13 | Inspiration and help
Operating instructions
53 / 64
13.3.5
Error messages CleanJet
Error report
Cause
Cooking possible
Service (E) 25
Water volume cleanjet too low
The water quantity required by the
iCareSystem is too low.
–
Service (E) 26
Drain valve does not open
The ball valve cannot find the
open
position.
No
Service (E) 27
Drain valve does not close
The ball valve cannot find the
closed
position.
No
Service (E) 34.8
Data communication failed
The automatic clean does not work.
Yes
Service (E) 43.6
Solenoid valve failed
The internal water supply is not closing.
Only the convection mode is
available at the moment.
Service (E) 47.1
Pump failed
The waste water pump is defective.
Yes
Service (E) 47.2
Pump failed
The waste water pump is defective.
Yes
Service (E) 110
Cleanjet failed
An error occurred in the SC pump during
the automatic clean.
No
Service (E) 120
Cleanjet failed
An error occurred in the water level
recognition during the automatic clean.
No
13.3.6
Error messages Care
Error report
Cause
Cooking possible
Service (E) 42.4
Solenoid valve failed
The water supply is faulty.
Yes
Service (E) 43.4
Solenoid valve failed
The internal water supply is not closing.
Only the convection mode is
available at the moment.
Service (E) 49.1
Pump failed
The water supply is faulty.
Yes
Service (E) 49.2
Pump failed
The water supply is faulty.
Yes
13.3.7
Notification centre
Error report
Cause
Cooking possible
Service (E) 17
Unit data failed
The unit model is incorrect.
No
Service (E) 29
Electric compartment too hot
The board temperature is too high.
No
Service (E) 31.1
Core temperature sensor
failed
The core probe in the cooking cabinet is
defective.
Yes, but you cannot use the
core probe.
Service (E) 31.2
Core temperature sensor on
emergency run
The core probe in the cooking cabinet is
defective.
Yes, but you cannot use the
core probe.
Service (E) 34.16
The internal data communication is faulty.
Yes