9040 Low Voltage Control Unit Kit- Atex
EUROPEAN ATEX DIRECTIVE 94/9/EC, ANNEX II, 1.0.6
The following instructions apply to equipment
covered by certificate number Sira
11ATEX5240X:
1.
The equipment may be used with flammable
gases and vapors with apparatus groups II and
with temperature class T6.
2.
The equipment is only certified for use in
ambient temperatures in the range +12.8
C to
+40
C and should not be used outside this range.
3.
Installation shall be carried out by suitably
trained personnel in accordance with the
applicable code of practice e.g. EN 60079-
14:1997.
4.
Inspection and maintenance of this
equipment shall be carried out by suitably
trained personnel in accordance with the
applicable code of practice e.g. EN 60079-17.
5.
Repair of this equipment shall be carried out
by suitable trained personnel in accordance with
the applicable code of practice e.g. EN 60079-19.
6.
Putting into service, use, assembling, and
adjustment of the equipment shall be fitted by
suitably trained personnel in accordance with
the manufacturer's documentation.
Refer to the "Table of Contents" of this service
manual:
a.
Installation
b.
Operation
c.
Maintenance
d.
Parts Identification
7.
Components to be incorporated into or used
as replacement parts of the equipment shall be
fitted by suitably trained personnel in accordance
with the manufacturer's documentation.
8. The certification of this equipment relies upon
the following materials used in its construction:
If the equipment is likely to come into contact with
aggressive substances, then it is the responsibility
of the user to take suitable precautions that
prevent it from being adversely affected, thus
ensuring that the type of protection provided by
the equipment is not compromised.
Aggressive substances: e.g. acidic liquids or
gases that may attack metals, or solvents that
may affect polymeric materials.
Suitable precautions: e.g. regular checks as
part of routine inspections or establishing from
the material's data sheets that it is resistant to
specific chemicals.
Refer to "Specifications" in the "Introduction"
section:
a.
All fluid passages contain stainless
steel or nylon fittings.
b.
High voltage cascade is encapsulated
with a solvent resistant epoxy.
9.
A recapitulation of the certification marking
is detailed in the "Atex" section, on the next
page, drawing numbers: 72562 and 80075.
10.
The characteristics of the equipment shall
be detailed e.g. electrical, pressure, and voltage
parameters.
The manufacturer should note that, on being
put into service, the equipment must be
accompanied by a translation of the instructions
in the language or languages of the country in
which the equipment is to be used and by the
instructions in the original language.
5
CP-11-01
Содержание 9040
Страница 2: ...CP 11 01...
Страница 29: ...9040 Low Voltage Control Unit Kit Operation NOTES CP 11 01 26...
Страница 33: ...9040 Low Voltage Control Unit Kit Maintenance NOTES CP 11 01 30...
Страница 36: ...9040 Low Voltage Control Unit Kit Maintenance Figure 11 9040 Cascade Control Unit Block Diagram 33 CP 11 01...
Страница 41: ...9040 Low Voltage Control Unit Kit Maintenance NOTES CP 11 01 38...
Страница 44: ...CP 11 01 40...
Страница 49: ...Models and specifications subject to change without notice 07 11...