9040 Low Voltage Control Unit Kit- Installation
INSTALLATION
!
W A R N I N G
>
The 9040 Cascade control unit MUST
be located outside the hazardous area.
(See NFPA-33, European Norms, and
Ransburg Literature “Operating Your
Electrostatic Coating System Safely”.)
>
The user MUST read and be familiar with
the SAFETY and SAFETY PRECAUTIONS.
>
This manual MUST be read and thoroughly
understood by ALL personnel who operate,
clean, or maintain this equipment! Special care
should be taken to ensure that the WARNINGS
and requirements for operating and servicing
safely are followed. The user should be aware
of and adhere to ALL local building and fire
codes and ordinances as well as NFPA-33 and
European Norms prior to installing, operating,
and/or servicing this equipment.
NOTE
>
As each installation is unique, this
information is intended to provide
gener-
al installation information for the 9040
Cascade control unit. Consult your au-
thorized Ransburg representative for
specific directions pertaining to the
installation of your equipment.
LOCATION
Install the 9040 Cascade control unit and external
cascade in an area outside the hazardous
location, where it will be protected from the
possibility of environmental intrusion, such as dust
or moisture, and ambient temperatures do not
exceed 49
°C (
120
F), but as close to the
applicator as possible to minimize the length of
low and high voltage cables. The control unit may
be free standing on any flat surface or rack
mounted in any 19-inch or Eurorack cabinet.
11
!
C A U T I O N
>
DO NOT locate the control unit near
or adjacent to heat producing equipment
such as ovens, high wattage lamps, etc.
NOTE
>
When rack mounting the 9040 Cas-
cade control unit in a 19-inch cabinet or
Eurorack, it may be necessary to
remove the rubber feet from the bottom
of the 9040 enclosure.
INPUT CONNECTIONS
For non-conduit installations, plug the
detachable AC line cord into the receptacle in
the rear of the 9040 Cascade control unit. Plug
the other end of the line cord into a properly
grounded 120-volt AC outlet.
NOTE
>
In general, conduit must be used for
approved AC installation; however, if
national and local codes permit, the AC
power may be supplied via the factory
supplied line cord. If conduit is utilized,
the control unit AC input wiring may be
routed through an optional explosion
proof switch mounted on or near the
spray booth where it will be convenient
to the operator.
CP-11-01
Содержание 9040
Страница 2: ...CP 11 01...
Страница 29: ...9040 Low Voltage Control Unit Kit Operation NOTES CP 11 01 26...
Страница 33: ...9040 Low Voltage Control Unit Kit Maintenance NOTES CP 11 01 30...
Страница 36: ...9040 Low Voltage Control Unit Kit Maintenance Figure 11 9040 Cascade Control Unit Block Diagram 33 CP 11 01...
Страница 41: ...9040 Low Voltage Control Unit Kit Maintenance NOTES CP 11 01 38...
Страница 44: ...CP 11 01 40...
Страница 49: ...Models and specifications subject to change without notice 07 11...