9040 Low Voltage Control Unit Kit- Safety
AREA
HAZARD
SAFEGUARDS
Tells where hazards
Tells what the hazard is.
Tells how to avoid the hazard.
may occur.
Spray Area /
This is a high voltage device that Parts being sprayed must be supported on conveyors
High Voltage
can produce electrical arcs
or hangers and be grounded. The resistance between
Equipment
capable of igniting coating
the part and ground must not exceed 1 Mega
.
materials.
(Reference NFPA-33, EN 60079.)
A safe distance must be maintained between the parts
being coated and the atomizer . A distance of at
least 1 inch for each 10 KV of power supply output
voltage is required at all times.
Parts must be supported so that they will not swing
and reduce the clearance specified above.
All electrically conductive objects in the spray area,
with the exception of those objects required by the
process to be at high voltage, must be grounded.
Unless specifically approved for use in hazardous
locations, the power supply and other electrical
equipment must not be used in Class I, Division 1 or
2 locations or in Zone 1.
CP-11-01
4