Vector Solo Waterborne Applicators - Maintenance
43
Ransburg
3. With the 79330 fitting, hold the hose in one hand
and press a 6mm or 1/4" t-handle allen wrench
into the hex in the part while turning clockwise.
Tighten till cap is approximately .8 mm (1/32")
from the swivel nut.
Resistance Test
1. If the hose is changed, the resistance must
be checked. Using a Meg Ohm meter at 1000V
measure the resistance from the lug of the ground
wire to the body of the QD (79868) or the swivel
nut (79930). The reading must be less than .5
Mega Ohms resistance end to end.
Figure 79: Tightening 79930 Fitting
4. With the 79868 DQ fitting, hold the hose in one
hand and press against a firm surface while turning
the body wrench flat clockwise. Tighten till cap is
approximately .8 mm (1/32") from the QD base.
Figure 80: Tightening 79868 QD Fitting
Figure 81: Air Hose Resistance Test