Vector Solo Waterborne Applicators - Installation
18
Ransburg
The waterborne hose may need to
be trimmed to proper length (approxi-
mately 213mm ( 8 3/8") measured from
the top face of the bracket.
NOTE
Figure 9: Tighten Hose Onto Bracket
Figure 10: Install Hose Onto Barrel
8. Trigger the applicator with fluid off. Look for air
leaks in any connections.
9. Activate fluid, check for leaks with solvent.
Flush if required. (See "Operation" section for
sequence.)
c. Tighten the thin jam nut [4] onto the bulkhead
connector [2]. Tighten the Nylo-Seal nut [5]
onto the bulkhead connector [2].
d. Place the connector nut [6] and two (2)
ferrules [7 and 8] onto the short stopper
hose. Insert hose into the barrel and tighten
the connector nut [6] to 40 - 45 in-lbs.
˜
AH-08-03.6