Vector Solo Waterborne Applicators - Installation
15
Ransburg
Filters
1. Install an air filter assembly on the air outlet
of the main air regulator. The filter should be 5
micron with a maximum working pressure of at
least 6.9 bar (100 psig). Screw the fitting into the
filter inlet. The filter MUST be installed with the
arrow pointing in the direction of flow. (Refer to
the appropriate Filter Assembly manual for Instal-
lation Instructions.)
2. Ransburg recommends that a fluid filter be
installed at the output of the fluid supply (pressure
pot, pump, circulating system, etc.). It is the end
user's responsibility to install the proper filter that
meets their system's requirements.
79901 VECTOR SOLO
WATERBORNE
INSTALLATION
The user
MUST
read and be familiar
with the "Safety" section of this manual.
This hand held device is intended to be
used by trained personnel ONLY.
This manual
MUST
be read and thor-
oughly understood by
ALL
personnel who
operate, clean, or maintain this equipment!
Special care should be taken to ensure that
the warnings and requirements for operat-
ing and servicing safely are followed. The
user should be aware of and adhere to
ALL
local building and fire codes and ordinanc-
es as well as NFPA, OSHA, and all related
country safety codes prior to installing, op-
erating, and/or servicing this equipment.
Personnel
MUST
be
GROUNDED
to
prevent a shock or spark during electrostat-
ic operation.
Install and route the hoses so they are
NOT
exposed to temperatures in excess of
49
°
C (120
°
F) and so that all hose bends
are
NO LESS
than a 15cm (6-inch) radius.
Failure to comply with these parameters
could cause equipment malfunction that
might create
HAZARDOUS CONDITIONS!
W A R N I N G
!
Clean Dry Air
Air used for the 79901 Vector Solo waterborne
applicator should be clean and dry.
Ransburg specifies clean and dry air as:
Class 3 air quality, which is defined as a 5 micron
particle size and has a dew point of -4F (-20C).
The relative humidity of the air should be 5%.
AH-08-03.6