![R&S FSW-K7 Скачать руководство пользователя страница 279](http://html1.mh-extra.com/html/rands/fsw-k7/fsw-k7_user-manual_3082493279.webp)
Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
279
User Manual 1173.9240.02 ─ 23
11.4.8.6
Scaling for AF Evaluation
These settings are only available for AF evaluations.
Useful commands described elsewhere:
●
[SENSe:]ADJust:SCALe[:Y]:AUTO[:CONTinuous]
●
●
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RPOSition
●
DISPlay[:WINDow<n>]:TRACe<t>:Y:SPACing
Specific commands:
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RVALue
...................................................... 279
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RVALue
<Value>
This command defines the reference value assigned to the reference position in the
specified window. Separate reference values are maintained for the various displays.
Suffix:
<t>
.
irrelevant
Parameters:
<Value>
*RST:
AM time domain: 0 PCT; FM time domain: 0 Hz;
PM time domain: 0 rad; AM spectrum: 100 PCT;
FM spectrum: 250 kHz; PM spectrum: 10 rad;
Example:
DISP:TRAC:Y:RVAL 0
Sets the value assigned to the reference position to 0 Hz
Manual operation:
See
11.4.8.7
Scaling for RF Evaluation
These commands are required for RF evaluations and the result summary.
●
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RPOSition
●
DISPlay[:WINDow<n>]:TRACe<t>:Y:SPACing
●
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]
●
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:MODE
11.4.8.8
Units
The units define how the demodulated data is displayed.
UNIT<n>:ANGLe
<Unit>
This command selects the unit for angles (for PM display, <n> is irrelevant).
Configuring the Measurement