Integrated Sensor System
Valve Box Installation
To install the valve boxes:
At each valve box, locate and identify the wire
path and the sensor cable as shown in Figure 11.
Use a wire cutter to cut the wire path, and insert
the two ends of the wire path and the end of the
sensor cable into the valve box.
Using a wire stripper and Rain Bird DB-series
wire connectors, connect the sensor cable to the
wire path as shown.
Table 5 - Cable Wires
Cable
Data
Power
Ground
Wire Path
Green
Red
White
TSM-3 (Type 3)
Blue
Red
Black
Replace the soil and turf carefully around the
valve box so that after a short healing period the
installation is no longer visible.
Sensor
Cable
Wire Path
Valve Box
Trench
Trench
Connect
Data Wires
Connect
Power Wires
Rain Bird DB
Wire Connector
Connect
Ground Wires
Figure 11 - Valve Box Wiring Diagram