34
Integrated Sensor System
The “Enter Password” message is
displayed. Enter 4132.
If the correct password is not
entered after 10 seconds,
“Invalid password or timeout” is
displayed. Press RETRY.
The Diagnostic 1 screen
appears; press the >> button
twice.
Diagnostic 1
EXIT
WAKE
Radio Status:
Awake
RSSI:
Battery:
Packet:
-78 dBm
4.89
0.0%
MED
HIGH
The Diagnostic 3 screen
appears. “Press M-TEST key to
start manufacturing functional
test” is displayed. Press M-TEST.
Run Diagnostic Test 3
Performs a manufacturing
functional test that displays
the status of various ISDL-2400
hardware components.
NOTE:
Only one sensor should
be connected to each channel
when performing this test.
Turn the dial to
SPECIAL FEATURES
The Features screen appears.
Press and hold the second
and third buttons until the
Diagnostic screen appears.
Features
ISDL Version 1.0
Radio Version: 804B
Node 13A200 403B6CE2
Host 13A200 4033F656
DIAGNOSTIC
Содержание ISDL-2400