QRAE II
User’s Guide
Page 79
1.
Attach the regulator to the Calibration Gas cylinder.
Important!
Make sure you have the correct calibration gas in the correct
concentration. Also make sure that the calibration gas is not beyond its “Best
when used by” date, which is stamped on the cylinder’s label.
2.
Turn on the regulator to start the Calibration Gas flow.
3.
Attach a hose to the Monitor gas inlet and to the regulator.
4.
Press [MODE] until OK is highlighted.
5.
Press [Y/+] to start calibration.
You should see a countdown from 60 seconds:
Calibration
in progress ... 60
Note:
If you see the following message, check that the gas is flowing and the hose is
attached:
No Gas Flow... Apply gas or hit any key to start.
If the flow is correct, a pump icon is shown at the right of LCD screen. If the flow is not
correct, the pump icon and the red LED flashes and the audible alarm beeps).
Bump Testing & Calibrating QRAE II (Diffusion Version)
RAE Systems recommends that a bump test be performed on the QRAEII before the
monitor is used or being put into service. A bump test is defined as a brief exposure
of the monitor to the calibration gas and the sensors to show response and trigger the
lowest alarm set point for each sensor.
•
The QRAEII Multi Gas detector must be calibrated if it does not pass a Bump
Test, or at least once every 180 days, depending on use and sensor exposure to
poisons and contaminants.
•
Calibration intervals and bump test procedures may vary due to national
legislation.
Note:
Bump test and calibration can also be performed by using the RAE Systems
AutoRAE Lite For QRAE II docking station.
Содержание QRAE II
Страница 2: ...Copyright 2011 RAE Systems Inc...
Страница 35: ...QRAE II User Guide Page 33 The following diagram shows the navigation of this set of submenus...
Страница 39: ...QRAE II User Guide Page 37...
Страница 42: ...QRAE II User Guide Page 40 The diagram below shows the difference between the two startup modes...
Страница 47: ...QRAE II User Guide Page 45 5 Alarm Signal Summary Note Backlight automatically turns on when QRAE II alarms...
Страница 63: ...QRAE II User Guide Page 61 4 Push the screws from the back of the monitor to pop the cover off the front...
Страница 72: ...QRAE II User s Guide Page 70 poisons and contaminants Range Resolution Response Time LEL 0 100 1 15 sec...
Страница 91: ...QRAE II User s Guide Page 89 Alarm Signal Summary Note Backlight automatically turns on when QRAE II alarms...
Страница 92: ...P N 020 4100 000 Rev F May 2013...