QRAE II User Guide
Page 32
Change Average Alarm Limit.
This function allows you to selectively set the STEL
(short term exposure limit) of individual sensors in the QRAE II. Note: This function
does not include LEL or oxygen sensors.
1.
Select a sensor by pressing [MODE] until the sensor’s name is highlighted.
2.
Press [MODE] to step through the sensor’s digits.
3.
Press [Y/+] to increase the number from 0 through 9. Once the number 9 is
reached, pressing [Y/+] causes the numbers to “wrap around” to 0 and count up
again.
4.
Press and hold [MODE] for 3 seconds to advance to the next sensor.
5.
Follow the same procedure as steps 2 and 3.
After you have performed all necessary modifications:
6.
Press [MODE] to advance to Save or Quit.
7.
With Save selected, press [Y/+] to save your settings, or [MODE] to advance to
Quit (without saving settings).
Back.
Press [MODE] to return to the top of the Change Alarm Limits menu, or press
[Y/+] to return to the top of the Normal Mode menu.
4.6
Change Datalog
The QRAE II calculates and stores the gas readings based on a user-specified datalogging
period and the type of measurement. Average, peak and minimum values can be stored
for each sensor during each datalogging interval. The datalogging interval can be
programmed from one second to 3,600 seconds (60 minutes) in 1-second intervals. In
addition, serial number, last calibration date, and alarm limits are stored. All data are
retained in non-volatile memory for later download to a PC.
There are six submenus to Change Datalog:
Clear All Data
Change Datalog Period
Select Data Type
Enable/Disable Datalog
Start/Stop Datalog
Select Memory Full Type
Содержание QRAE II
Страница 2: ...Copyright 2011 RAE Systems Inc...
Страница 35: ...QRAE II User Guide Page 33 The following diagram shows the navigation of this set of submenus...
Страница 39: ...QRAE II User Guide Page 37...
Страница 42: ...QRAE II User Guide Page 40 The diagram below shows the difference between the two startup modes...
Страница 47: ...QRAE II User Guide Page 45 5 Alarm Signal Summary Note Backlight automatically turns on when QRAE II alarms...
Страница 63: ...QRAE II User Guide Page 61 4 Push the screws from the back of the monitor to pop the cover off the front...
Страница 72: ...QRAE II User s Guide Page 70 poisons and contaminants Range Resolution Response Time LEL 0 100 1 15 sec...
Страница 91: ...QRAE II User s Guide Page 89 Alarm Signal Summary Note Backlight automatically turns on when QRAE II alarms...
Страница 92: ...P N 020 4100 000 Rev F May 2013...