![Rae microrae Скачать руководство пользователя страница 26](http://html2.mh-extra.com/html/rae/microrae/microrae_user-manual_3372512026.webp)
MicroRAE User’s Guide
26
8. Modes Of Operation
The MicroRAE has two user modes, selectable through ProRAE Studio II.
8.1. Basic User Mode
In Basic User Mode, some restrictions are applied, including password protection that guards
against entering Programming Mode by
unauthorized personnel.
8.2. Advanced User Mode
In Advanced User Mode, there are no access restrictions (you do not need a password), and the
MicroRAE provides the indications and data you need most for typical monitoring applications.
9. Programming
The menu in Programming Mode is to adjust many of the MicroRAE’s settings, calibrate sensors,
and initiate communication with a computer. It has the following submenus:
•
Calibration
•
Sensor On/Off
•
Clear Datalog
•
Monitor Setup
•
Set Radio (Wireless)
Note:
Some settings are only visible and can only be changed in ProRAE Studio II. This requires
connecting the instrument to a computer running ProRAE Studio II and having administrative
privileges. For a list of which parameters can be set in Programming Mode on the MicroRAE, in
ProRAE Studio II, or both
9.1. Enter Programming In Basic Mode
1.
To enter Programming Mode, press and hold [MODE] and [Y/+] until you see the Password
screen.
2. Input the 4-digit password:
•
Increase the number from 0 through 9 by pressing [Y/+].
•
Step from digit to digit using [MODE].
•
After inputting the password’s four digits, advance to “?”
•
Press [Y/+] to register the password and enter Programming Mode. If you receive the
message “PASS ERR RETRY?” press [Y/+] to re-enter the password. Otherwise, press
[MODE] to return to the main screen.
If you make a mistake, you can cycle through the digits by pressing [MODE] and then using
[Y/+] to change the number in each position.
Note:
The default password is 0000.
Note:
The password screen only appears when you enter the Programming Mode the first time
after turning the instrument on in Basic Mode. If you have input the correct password, you do not
have to input it again to enter Programming Mode until you turn the instrument off and on again.