5.2 Configuring RADWIN 2000 Alpha and RADWIN
Alpha Connectorized ODUs as Hubs
RADWIN
Manager release
11.0
and above detects
if the managed
device
supports the
browser
UI,
and if so, redirects
you
to
use
the
browser
UI
instead.
1. Connect to ODU:
o
From a laptop in the field, disconnect the PoE from the communications
network (LAN Connection) and connect the laptop.
o
From the NOC, keep the PoE connected to the LAN.
2. Enter the IP address of the ODU that is to be the RT
‐
A(HBS).
3. Log on to the RADWIN Manager application as "Installer".
4. From main window of the RADWIN Manager application, click the
Configuration
button
5. Choose the
Operations
tab.
6. Click
Change
ODU Mode
.
7. Click
RT
‐
A(HBS)
and follow the on
‐
screen instructions.
5.3 Defining RADWIN 2000 E ODUs as Hubs
1. Connect to the required ODU using the browser user interface.
2. In the Quick Setup wizard, define the Device Type as Hub or Client and click
NEXT
.
If the device type was changed, the device will reboot. After reboot, complete the
quick wizard to activate the device.