RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
33
Private
MIB
Parameters
Chapter
C
winlink1000HbsAirUpUtilMill
1.3.6.1.4.1.4458.1000.3.1.1
6
Integer
RO
Sector
Air
Interface
utilization
in
the
Uplink
direction
(thousandths).
The
average
number
of
timeslots
that
were
used
in
the
UL
(by
all
the
links)
out
of
the
entire
number
of
timeslots.
winlink1000HbsAirDownTrafficKbps 1.3.6.1.4.1.4458.1000.3.1.1
7
Integer
RO
Average
data
throughput
(expressed
in
Kbps)
transmitted
in
the
DL
towards
all
the
SUs
during
the
last
second.
winlink1000HbsAirUpTrafficKbps
1.3.6.1.4.1.4458.1000.3.1.1
8
Integer
RO
Average
data
throughput
(expressed
in
Kbps)
received
in
the
UL
from
all
the
SUs
during
the
last
second.
winlink1000HbsAirCompressedMon
Sec
1.3.6.1.4.1.4458.1000.3.1.1
9
DisplayString
RO
One
string
that
holds
the
4
Utilization
per
Sector
values:
DownUtil
(2
bytes)
UpUtil
(2
bytes)
DownTraffic
(4
bytes)
UpTraffic
(4
bytes).
winlink1000HbsAirDelayVsTputOpt
1.3.6.1.4.1.4458.1000.3.1.2
0
Integer
RW Delay
vs.
Throughput
optimization
type:
1
=
Delay
sensitivity
2
=
Throughput
optimized
winlink1000HbsAirUCBPMinCS
1.3.6.1.4.1.4458.1000.3.1.2
1.1
Integer
RW Minimal
contention
slot
length
used
for
UCBP
algorithm
(in
ms.)
between
5
‐
20ms.
winlink1000HbsAirUCBPSharingPer
centage
1.3.6.1.4.1.4458.1000.3.1.2
1.2
Integer
RW Sharing
percentage
used
by
UCBP
algorithm
(15
‐
75)
winlink1000HbsBridgeAgingTime
1.3.6.1.4.1.4458.1000.3.2.1
Integer
RW Timeout
in
seconds
for
aging.
winlink1000HbsBridgeVlanTable
N/A Holds
the
bridge
Vlan
operations
towards
all
the
registered
HSUs.
winlink1000HbsBridgeVlanEntry
N/A HBS
bridge
Vlan
table
entry.
INDEX
{
winlink1000HbsBridgeVlanIndex
}
winlink1000HbsBridgeVlanIndex
RO
HBS
bridge
Vlan
table
index.
winlink1000HbsBridgeVlanIngress
RW HBS
bridge
Vlan
ingress.
winlink1000HbsBridgeVlanEgress
RW HBS
bridge
Vlan
egress.
winlink1000HbsBridgeVlanFilterIn
RW HBS
bridge
Vlan
filter
in.
winlink1000HbsBridgeVlanFilterOut
RW HBS
bridge
Vlan
filter
out.
winlink1000HbsBridgeVlanDoubleT
ag
RW HBS
bridge
Vlan
double
tag.
winlink1000HbsBridgeVlanDefaultI
d
RW HBS
bridge
Vlan
default
id.
winlink1000HbsBridgeMembership
Table
N/A Holds
the
bridge
membership
relations
for
all
the
registered
HSUs.
winlink1000HbsBridgeMembership
Entry
N/A HBS
bridge
membership
table
entry.
INDEX
{
winlink1000HbsBridgeMembershipIndex
}
winlink1000HbsBridgeMembershipI
ndex
1.3.6.1.4.1.4458.1000.3.2.3.
1.1
Integer
RO
HBS
bridge
membership
table
index.
winlink1000HbsBridgeMembership
State
1.3.6.1.4.1.4458.1000.3.2.3.
1.2
Gauge
RW HBS
bridge
membership
state
bitmap.
Each
bit
represents
Blocked/Opened
relation
(membership)
between
two
HSUs.
Blocked=0
(bit)
Opened=1
(bit).
This
object
holds
the
relation
to
32
HSUs.
winlink1000HbsBridgeMembership
State2nd
1.3.6.1.4.1.4458.1000.3.2.3.
1.3
Gauge
RW HBS
bridge
membership
state
bitmap.
Each
bit
represents
Blocked/Opened
relation
(membership)
between
HSU
and
LAN/Stack
port
of
the
HBS.
Blocked=0
(bit)
Opened=1
(bit).
Only
2
bits
are
used.
winlink1000HbsBridgeFloodOverloa
dProtect
1.3.6.1.4.1.4458.1000.3.2.4
Integer
RW Flood
overload
protection
1
‐
Enabled
2
‐
Disabled.
Table
C
‐
2:
Private
MIB
Parameters
(Sheet
28
of
32)
Name
OID
Type
A
cce
ss
Description
Содержание 2000 C PLUS
Страница 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Страница 17: ...Part 1 Basic Installation Release 3 5 70...
Страница 139: ...Part 2 Site Synchronization Release 3 5 70...
Страница 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Страница 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Страница 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Страница 189: ...Part 4 Field Installation Topics Release 3 5 70...
Страница 219: ...Part 5 Product Reference Release 3 5 70...
Страница 296: ......