To change the time-out period
This example changes the time-out period of all connections on the designated real server to 4
minutes.
Maximum Connections for Real Servers
You can set the number of open connections each real server is allowed to handle for SLB. To set the
connection limit, enter the following:
Values average from approximately 500 HTTP connections for slower servers to 1500 for quicker,
multiprocessor servers. The appropriate value also depends on the duration of each session and how
much CPU capacity is occupied by processing each session. Connections that use many Java or CGI
scripts for forms or searches require more server resources and thus a lower maxcon limit. You may
want to use a performance benchmark tool to determine how many connections your real servers
can handle.
When a server reaches its maxcon limit, Alteon no longer sends new connections to the server.
When the server drops back below the maxcon limit, new sessions are again allowed.
You can also set the max connections mode to physical (default) or logical. Real servers with the
same IP address must be set to the same maxcon connection mode.
•
Real servers with the same IP address set to maximum connection mode physical must all have
the same maxcon value. The maxcon value is the maximum number of connections that the real
servers both support.
•
Real servers with the same IP address set to maximum connection mode logical can each have
different maxcon values. The maxcon value is the maximum number of connections that each
logical real server supports individually.
>> # /cfg/slb/real <real server number>
(Select the real server)
>> Real Server# tmout 4
(Specify an even numbered interval)
>> # /cfg/slb/real <real server number>
(Select the real server)
>> Real Server 1 # maxcon 1600
(Allow 1600 connections maximum)
Current max connections mode [logical]:
Enter new max connections mode
[physical/logical][logical]: