4.2. Annual Service (Required)
The following procedures should be followed annually to maintain the AIRaider™:
•
Clean solenoids and switch coil locations.
•
Check any hose connections.
•
Check and/or clean the blower air intake filter.
•
Check and/or clean any filters or strainer installed on the inlet line to the AIRaider™.
•
Check and clean inlet screen on pump.
•
Using a wet / dry vacuum, clean sediment from bottom of aeration tank if necessary.
•
Clean (if necessary) tank and diffusers of all mineral build-up.
•
Chlorinate tank and lines by pouring ¼ cup of chlorine into the tank.
•
Check all control panel connections and electrical components (blower, blower brushes, pump, alarm/buzzer,
fuses, etc.) for proper operation.
•
Check float switches for proper operation.
•
Inspect vent line for possible obstructions.
•
Run system through two cycles to ensure good working order.
•
Perform Water Test.
IMPORTANT SERVICE NOTES:
Every 3 years during the annual service replace any hoses and Blower Brushes.
Every 5 years during the annual service replace the solenoid valves and Blower Brushes.