3. RETESTING
After AIRaider
™
installation, the installer should perform another water analysis to ensure proper system
performance. This sampling should be performed one week after the date of installation.
Sampling Procedure:
1.
Remove aerator from faucet or spigot, if applicable.
2.
Run water so that the AIRaider™ operates for two cycles.
3.
Turn off water for 5 minutes.
4.
Turn water on and proceed with sampling as per the laboratory instructions.
4. MAINTENANCE
Proper maintenance of the AIRaider™ can prevent possible system failure and provide years of trouble-free
service.
4.1. Six-Month Service (Recommended)
The following procedures should be followed to maintain the AIRaider™:
•
Check and/or clean the blower air intake filter.
•
Check and/or clean any filters or strainer installed on the inlet line to the AIRaider™. In installations
with particularly high levels of sediment cleaning of filters may be required more frequently.
•
Check and clean inlet screen on pump.
•
Using a wet / dry vacuum, clean sediment from bottom of aeration tank if necessary.
•
Clean (if necessary) tank and diffusers of all mineral build-up.
•
Chlorinate tank and lines by pouring ¼ cup of chlorine into the tank.
•
Check all control panel connections and electrical components (blower, blower brushes, pump, alarm/
buzzer, fuses, etc.) for proper operation.
•
Check float switches for proper operation.
•
Inspect vent line for possible obstructions.
•
Run system through at least two cycles to ensure good working order.