background image

4

1.2 Fan speed

Displays the actual value of the fan speed. In case the fan speed value drops under a set 
value, the icon will turn red and an acous  c signal will sound. To set the speed limit, pre-
ss the fan icon and change the speed value a  er the numerical entry dialogue appears. 
Con

fi

 rm the se   ngs by pressing the 

OK

 key.

1.3 Daily hectare-meter

Displays the actual state of the sown area up to a maximal value of 99.9 ha. The dis-
played value can be reset by shortly pressing the daily hectare-meter indicator.

1.4 Summary hectare-meter

Displays the total sown area. This value cannot be reset by the user. Rese   ng is possible 
only by a service interven  on.

1.5 SH1 and SH2 sensors of seed level in hoppers

Displays the actual state of seed in the hopper. When the seed level drops below the 
level of the sensor 

fi

   ed in the hopper, the empty hopper symbol will turn red and an 

acous  c signal will sound.

1.6 Level sensors adjustment

On the sensor rear side there is a small screw under which the adjus  ng screw of the 
sensor sensi  vity is located.

1.7 A1 sensor of seeding

Displays the actual state of seed passing to the seeding hoses. 
•  In case the seed is passing through the seeding sensor, a green box symbol is dis-

played in the corresponding posi  on.

•  In case the seed is not passing through the par  cular sensor, a yellow box symbol is 

displayed in the corresponding posi  on.

•  In case the sensor is not connected, is not communica  ng or it is faulty or damaged, 

a red box symbol is displayed in the corresponding posi  on.

1.8 Actual date and time

Displays the actual   me. The   me is set automa  cally according to the tablet system 

 me and is corrected by the GPS/Glonass signal during the opera  on. In case the GPS/

Glonass signal is unavailable, the   me is synchronized with the tablet   me upon the 
entry into the second screen. 

Содержание A100

Страница 1: ...A100 control system instruc on manual Issue date 07 2014 ...

Страница 2: ......

Страница 3: ...a on of tramlines Pre emergent marking of tramlines Indica on of minimal level of seed in hoppers 2x Assembly travel speed measuring Actual date and me Fan speed indica on Seeding mechanism speed indica on Daily hectare measuring Summary hectare measuring Automa c seeding test Seeding mechanism driven by a motor up to 4 motors Con nuous regula on of the seeding dose during sowing Drill ligh ng con...

Страница 4: ...e necessary to monitor during the sowing process and enables to change the parameters of the tramline seeding dose fan speed limits doser 1 and doser 2 seeding dose all this during the course of the opera on Screen No 2 Serves for the user to input the parameters of the seeding test for dosers 1 to 3 the number of seeding sensors and their sensi vity the C factor for the travel speed induc on scan...

Страница 5: ...This will cause inaccuracy of the sown dose and reading distor on of the hectare meter radar it is necessary to install it so it will not be affected by e g the rota ng wheels of the trac le machine e g a tractor or by a large cloud of dust or other solid par c les flying off of the tractor wheels or the seed drill itself This will again cause increa sed inaccuracy of the sowing and hectare meter va...

Страница 6: ...or fi ed in the hopper the empty hopper symbol will turn red and an acous c signal will sound 1 6 Level sensors adjustment On the sensor rear side there is a small screw under which the adjus ng screw of the sensor sensi vity is located 1 7 A1 sensor of seeding Displays the actual state of seed passing to the seeding hoses In case the seed is passing through the seeding sensor a green box symbol i...

Страница 7: ...l In case the seeding mechanism stops during drill opera on a zero speed value is displayed and an acous c signal is sound to alert the operator about this serious fault In case the speed value is lower or higher than the required speed the speed numerical value is highlighted in red and an acous c signal is sound This signals to the operator that he must either reduce the seeding assembly travel ...

Страница 8: ...e seed drill and sprayer widths is set the number of rides is calculated as zero and all sowing sides are highlighted in grey The tramline se ngs and the state of the counter are stored in the internal memory of the unit even a er turning the system off A er turning the feeding power on all data are set to the state as they were before turning off 1 12 Tramline automatic mode The tramline crea on is...

Страница 9: ...me during opera on Controlling the drill hydraulics 1 16 Hydraulics turning on and off Pressing this key will turn on all hydraulic controlling func ons In case the hydraulics are not turned on none of the hydraulic func ons controlling keys will be func onal By pressing the key again the hydraulics controlling func ons are turned off 1 17 Drill unfolding Pressing this key will start the drill unfo...

Страница 10: ...n with the control unit via BLUE TOOTH If the symbol is not yellow colored the tablet is disconnected from the control unit and it cannot be controlled The following no ce is displayed on the tablet This symbol informs the user that the GPS Glonass signal is available In case the drill is equipped with and controlled by the GPS Glonass it is necessary to wait un l the symbol turns yellow before st...

Страница 11: ...9 Screen No 2 Description of the screen No 2 2 1 Seeding test This screen enables adjustment of the seeding test for the doser 1 to 3 ...

Страница 12: ...m the doser during the test must be caught into a suitable container or a bag Allow the doser to rotate un l the required amount of seed fills the container A er the test ends weigh its weight and input the value according to the following table 2 1 5 2 1 5 Entering the seed weight A er stopping the seeding test it is necessary to enter the weight of the seed which has been dosed during the seedin...

Страница 13: ...rder for the sensor to evaluate that the seeding is correct and SOWS In case less than 5 pieces of seed passes through within 1 second the sensor evaluates this as the seed is not passing through i e DOES NOT SOW 1 For small seeds such as poppy and rape the recommended value is 3 to 12 2 For medium sized seeds such as wheat and barley the recommended value is 30 to 100 3 For large seeds such as co...

Страница 14: ...ks are created the pre emergent marking automa cally lowers Upon opening of the val ves the pre emergent marking raises By pressing the key again the pre emergent tramline marking func on turns off 2 4 6 Markers automatics Pressing this key will turn on the func on of automa c switching over of the markers at the dead centre The key will be highlighted in yellow By this the automa c switching over ...

Страница 15: ... the symbol 2 6 2 Setting the circumference of the travel speed sensor wheel Press the symbol to set the wheel circumference In the entering numerical dialogue input the new value and confirm it by pressing the OK key The value will be displayed under the symbol A en on the value must be set in millimetres 2 6 3 Setting the C factor Firstly it is necessary to mark out a 100 meters long straight pa...

Страница 16: ...folding Press the key set the required value in the se ng dialogue and confirm it by pressing the OK key The new value will be automa cally stored in the memory 2 7 3 Drill raising Press the key set the required value in the se ng dialogue and confirm it by pressing the OK key The new value will be automa cally stored in the memory 2 7 4 Drill lowering Press the key set the required value in the s...

Страница 17: ... V Dashboard mains feeding voltage in volts Amperage 0 A Current bleed by the unit from the dashboard mains in amperes Power Consump on 0 W Total power consump on in wa s RADO AGRO s r o Control system manufacturer HW MU V0 14 01 Controlling unit hardware version FM A100 1 1 2 Controlling unit firmware version May 28 2014 12 14 35 Controlling unit firmware crea on date PN A100CB Controlling unit t...

Страница 18: ...16 ...

Страница 19: ......

Страница 20: ...RADO AGRO s r o Tečovice 309 763 02 Zlín 4 Czech Republic ...

Отзывы: