11
2.2 Seeding sensors setting
This
fi
eld of display serves for se ng the number of connected seeding sensors and their scanning sensi vity.
2.2.1 Setting the number of seeding sensors
Pressing this key will allow to set the number of sensors connected to the control unit
bus. This value is set by the manufacturer and is intended for service purposes only.
2.2.2 Setting the seed passage scanning sensitivity
The range of the sensor sensi vity is from 1 to 255. The value depends on the size of the
seed and the selected seeding dose. Se ng the sensi vity to 5 means that minimally
5 pieces of seed must pass through the sensor within 1 second in order for the sensor
to evaluate that the seeding is correct and “SOWS”. In case less than 5 pieces of seed
passes through within 1 second, the sensor evaluates this as the seed is not passing
through, i.e. “DOES NOT SOW”.
1. For small seeds, such as poppy and rape, the recommended value is 3 to 12.
2. For medium-sized seeds, such as wheat and barley, the recommended value is 30 to
100.
3. For large seeds, such as corn and bean, the recommended value is 10 to 30.
2.3 Lighting functions
2.3.1 Seed drill lighting
Pressing this key will turn on the seed drill ligh ng. Press it again to turn the ligh ng o
ff
.
2.3.2 Hopper lighting
Pressing this key will turn on the ligh ng inside the hopper. Press it again to turn the
ligh ng o
ff
.
2.3.3 Seeding mechanism lighting
Pressing this key will turn on the ligh ng of the seeding mechanism. Press it again to
turn the ligh ng o
ff
.