EPC-5A Hardware & Software Reference Manual
Page 100
9
9
NOT READY READING DRIVE ...
Problem:
This is usually caused by not fully inserting a diskette into the floppy
drive.
Solution(s): Eject the floppy diskette and reinsert making sure that the diskette
seats completely into the floppy drive.
PARITY ERROR IN SEGMENT ...
Problem:
This could be a software error (reading a nonexistent memory area) or
a true hardware failure.
Solution(s): Attempt to repeat the error. If the error occurs during the execution of
your own proprietary software, verify that the memory location
specified in your software is valid.
PRESS A KEY TO REBOOT
Problem:
A C: drive partition exists but is not set active.
Solution(s): Run your operating system disk partitioning program (like FDISK)
and set the primary partition active.
REAL TIME CLOCK ERROR - RUN SETUP
Problem:
The battery-backed TOD clock is incorrect.
Solution(s): Run the BIOS setup program to determine what is wrong, and correct
it. If the error occurs repeatedly, the EPC-5A’s battery has failed.
TESTING VME (VXI) INTERFACE FAILED
Problem:
The BIOS Post has detected that the VME or VXI registers are
invalid.
Solution(s): Attempt to repeat the error. Check all hardware and cable connections.
If the problem persists, there is a hardware error. Contact RadiSys
Technical Support.
Содержание EPC-5A
Страница 14: ...EPC 5A Hardware Software Reference Manual Page 6 1 1 NOTES ...
Страница 92: ...EPC 5A Hardware Software Reference Manual Page 86 6 6 NOTES ...
Страница 96: ...EPC 5A Hardware Software Reference Manual Page 90 2 2 7 7 NOTES ...
Страница 107: ...Chapter 9 Troubleshooting Error Messages Page 101 9 9 ...
Страница 122: ...EPC 5A Hardware Software Reference Manual A A Page A 6 NOTES ...
Страница 134: ...EPC 5A Hardware Software Reference Manual Page C 10 C C NOTES ...
Страница 138: ...EPC 5A Hardware Software Reference Manual Page D 4 D D NOTES ...
Страница 156: ...EPC 5A Hardware Software Reference Manual Page I VI NOTES ...