background image

19

4

LEDS AND EXTERNAL INTERFACES

Face plate interfaces

The external interfaces on the RTM face plate include a USB port, two external SAS ports, an 
RS-232 serial port, two SFP sockets, and a reset button.

Figure 4

 shows the location of the interfaces on the RTM face plate.

Figure 4. RTM face plate

Link status LED

Port status LED

Link status LED

Port status LED

SFP sockets (2)

Hot swap LED (H/S)

Out of service LED (OOS)
Power Good LED (PWR)
HDD Activity LED (ACT)

RS-232 serial port

SAS ports (2)

USB port

Reset button

Содержание ATCA-5400 RTM

Страница 1: ...www radisys com PROMENTUM REAR TRANSITION MODULE REFERENCE ATCA 5400 007 03301 0000 August 2009 ...

Страница 2: ...mentum are registered trademarks of RadiSys Corporation AdvancedTCA ATCA and PIGMG are registered trademarks of PCI Industrial Computer Manufacturers Group LSI Logic is a registered trademark of LSI Logic Corporation All other trademarks registered trademarks service marks and trade names are the property of their respective owners ...

Страница 3: ...11 Installing SFPs 11 Configuration recommendations 11 Transceiver installation 11 Filler plug installation 12 Installing a hard disk drive 12 Updating the drive information record 12 Attaching the drive sled to the HDD 13 Mounting the hard disk drive and sled onto the RTM 14 Inserting the RTM into the chassis 14 Chapter 3 Configuring a Redundant Disk Array 15 Supported RAID configurations 15 Prep...

Страница 4: ...eset 27 Connectivity records for interface compatibility 27 Upgradeable components 27 Appendix A Specifications 29 Environmental specifications 29 Safety specifications 30 Mechanical dimensions 30 Electromagnetic compatibility EMC 31 Power consumption 32 Mean time between failures MTBF 33 Environmental assumptions 33 General assumptions 33 General notes 33 Appendix B IPMI Commands and Managed Sens...

Страница 5: ...For instructions on installing optional components into the RTM see Chapter 2 Installing FRUs on page 11 For instructions on installing the RTM into the shelf see the ATCA 4500 Compute Processing Module Installation Guide The simplified name of RTM will be used in place of ATCA 5400 for the rest of the manual The simplified name of CPM will be used in place of Compute Processing Module or ATCA 450...

Страница 6: ... this URL http www picmg org Other related documents CAN CSA C22 2 No 60950 1 03 Safety for Information Technology Equipment Version 2 Canadian Standards Association www csa ca April 1 2003 EN 60950 1 2002 Information Technology Equipment Safety General Requirements European Committee for Electrotechnical Standardization CENELEC www cenelec eu February 22 2002 IEC 60950 1 Information Technology Eq...

Страница 7: ...0 1 Safety for Information Technology Equipment Part 1 General Requirements Edition 1 Underwriter Laboratories www ul com April 1 2003 Electrostatic discharge WARNING This product contains static sensitive components and should be handled with care Failure to employ adequate anti static measures can cause irreparable damage to components Electrostatic discharge ESD damage can result in partial or ...

Страница 8: ...8 ...

Страница 9: ...P port link status LEDs USB Power Conversion Monitoring 3 3V 1 8V 5V 1 2V MMC Circuitry PWR EN x4 EN CPU0_RTM_RST To Alarm CPLD JTAG PCIe_RST x4 PCIe REF_CLK PCIE_REFCLK PCIE_ RX TX RS 232 Buffer SER0 SFP 2 RTM L from Zone3 RESET_0 RTM L To Alarm CPLD E Key GPIO Latch Temp Sen 75 00 MHz Clk 37 50 MHz Clk NVSRAM FLASH ROM CLK Primary Secondary Primary Secondary CPLD JTAG SERDES Buffers w PE EQ cont...

Страница 10: ...hard disk drive on page 12 For instructions on configuring a RAID see Chapter 3 Configuring a Redundant Disk Array on page 15 The RTM has two 1 gigabit Ethernet SFP sockets on its face plate that can facilitate external connections through the RTM to the CPM These rear Ethernet ports are usable when the Ethernet controller on the CPM is configured to route the connections to the RTM On the ATCA 45...

Страница 11: ...to protect the internal components of the RTM Transceiver installation The illustration shows the correct orientation for inserting an SFP transceiver The transceiver may vary in appearance but the same insertion guidelines should be used 1 Obey the ESD procedures in Electrostatic discharge on page 7 and make sure you are adequately grounded 2 Remove the RTM and the transceivers from their antista...

Страница 12: ...M without a hard disk drive HDD installed A separate HDD can be ordered from RadiSys and installed onto the RTM prior to installing the RTM into the shelf For information on suitable hard disk drives see the Promentum Component Compatibility Report in the AdvancedTCA downloads section of the Web site at www radisys com downloads The RTM ships with a sled for sliding the HDD into the correct mounti...

Страница 13: ...omponent side down on the drive sled with the HDD SAS SATA connector at the right 4 Hold the HDD and drive sled together and turn them upside down to access the screw holes 5 Screw the four supplied M3 screws through the sled holes shown in Figure 2 and into the corresponding holes on the HDD 6 Turn the HDD and drive sled right side up so the retaining screw head faces up Figure 2 HDD installation...

Страница 14: ...plate and then toward the RTM SAS SATA connector See Figure 2 on page 13 The hard disk drive SAS connector mates with the RTM SAS SATA connector 3 Secure the sled to the RTM by tightening the retaining screw with a screwdriver Inserting the RTM into the chassis After the hard disk drive is installed insert the RTM into the chassis The MMC will report the correct drive type because it was previousl...

Страница 15: ...disk drive or spare in the array RAID 1 integrated mirroring enhanced IME which provides striping and one copy of each stripe for redundancy At least 3 hard disk drives must be used with a maximum of 8 copies Up to two hot spare hard disk drives can be included in case one of the participating hard disk drives fails The available hard disk drive capacity is the smallest disk capacity in the array ...

Страница 16: ...ny existing data is deleted Table 1 Locations and SAS connections for eligible disks Disk location Connection to the RTM SAS SATA controller RTM with its SAS SATA controller hosting the RAID On board no action required HDD AMC on a CPM in the front slot hosting the RTM Zone 3 connectors no action required Another RTM Cable between the SAS 1 ports on each RTM see Figure 3 on page 17 HDD AMC on anot...

Страница 17: ...s shown Select it and press Enter Cabled Link PCB Traces Custom SAS Crossover Standard SAS Crossover External hard disk drive array enclosure ATCA 4500 CPM ATCA 5400 RTM HDD AMC Port 2 SAS SATA controller Port 1 SAS SATA driver Port 3 0 1 Port 2 Port 0 Port 1 0 1 0 1 SAS 1 0 1 0 1 0 1 0 1 0 1 0 1 Drive enumeration order 1 Local RTM hard disk drive 2 Local AMC hard disk drive 3 Upper SAS connector ...

Страница 18: ...clude in the array with a maximum of 10 Data on each hard disk drive in a striping array is deleted Note When two pairs of RTMs and CPMs are cabled together the hard disk drives are identified in the SAS BIOS screens by slot number instead of the SAS SATA port number The identification is as follows Slot 0 Local RTM hard disk drive on the RTM controlling the RAID Slot 1 Local HDD AMC hard disk dri...

Страница 19: ...32 serial port two SFP sockets and a reset button Figure 4 shows the location of the interfaces on the RTM face plate Figure 4 RTM face plate Link status LED Port status LED Link status LED Port status LED SFP sockets 2 Hot swap LED H S Out of service LED OOS Power Good LED PWR HDD Activity LED ACT RS 232 serial port SAS ports 2 USB port Reset button ...

Страница 20: ...he MMC Solid Ready for hot swap Long blink Activating the module after insertion Short blink Preparing for hot swap Off No hot swap activity in progress SFP 1 SFP 2 N A Link status Green or amber Controlled by the alarm CPLD over the RTM link bus Green 1000BASE connection Amber 10 100BASE connection Copper only Solid Link OK Blinking Link activity Off Link fail port disabled Port status Green or a...

Страница 21: ...configuration See Chapter 3 Configuring a Redundant Disk Array on page 15 SFF 8470 SAS crossover cable RS 232 serial port Gives rear management access to the CPM Configure the external computer s terminal emulator to 11200 Kbps 8 bits no parity 1 stop bit no flow control Console serial cable RJ 45 to 9 pin D shell RadiSys order code ATCA SERIAL CBL The same cable is included in shipments of the AT...

Страница 22: ... devices Table 4 and Table 5 show the Zone 3 pinout of the CPM Table 4 RTM connector P30 signals Row AB CD EF GH 1 12V_RTM 12V_RTM 12V_RTM 3 3V_IPMC RES_STATE RTM_PRSNT RTM_HS_LED RTM_EN 2 12V_RTM 12V_RTM 12V_RTM IPMC_INT IPMC_I2C_ CLK IPMC_I2C_ DAT USB_D USB_D 3 SERIAL_0_TX SERIAL_0_RX JTAG_TDI JTAG_TDO JTAG_TMS JTAG_TCK JTAG_TRST Future 4 SOCA SOCB INT_0 INT_1 RTML_TX RTML_RX RTML_CLK RTM_RESET ...

Страница 23: ..._TX AMC2_19_ RX AMC2_19_RX AMC2_20_ TX AMC2_20_TX AMC2_20_ RX AMC2_20_ RX 5 PCIE1_RX2 PCIE1_RX2 PCIE1_TX2 PCIE1_TX2 PCIE1_RX3 PCIE1_RX3 PCIE1_TX3 PCIE1_TX3 6 PCIE1_RX0 PCIE1_RX0 PCIE1_TX0 PCIE1_TX0 PCIE1_RX1 PCIE1_RX1 PCIE1_TX1 PCIE1_TX1 7 AMC4_17_TX RESET_7 AMC4_17_TX DEBUG_7 PCI1_ REFCLK PCI1_REFCLK AMC4_18_ TX AMC4_18_TX PCI0_ REFCLK PCI0_REFCLK 8 PCIE0_RX2 PCIE0_RX2 PCIE0_TX2 PCIE0_TX2 PCIE0_R...

Страница 24: ...4 LEDs and External Interfaces 24 ...

Страница 25: ...and SATA transfers Each of the eight SAS SATA PHYs on the controller is capable of 3 0 Gbps and 1 5 Gbps SAS and SATA link rates The controller supports SAS versions 1 0 and 1 1 as well as Serial ATA revision 1 0a The controller supports PCI Express receive and transmit data rates of 2 5 Gbps in each direction yielding a total bandwidth of 5 0 Gbps for each full duplex lane The controller supports...

Страница 26: ... file system on The hard disk drive on the RTM A SAS hard disk drive on the AMC because the SAS hard disk drive is accessible only through the RTM SAS SATA controller A remote hard disk drive connected by cable to a SAS SATA connector on the RTM A remote NFS server accessible only through an SFP port on the RTM WARNING Do not remove the RTM if the CPM is accessing the operating system via the RTM ...

Страница 27: ...ress port Two SerDes gigabit Ethernet ports The RTM connectivity records comply with the records defined for AMCs in the PICMG AMC 0 R2 0 Advanced Mezzanine Card Base Specification Upgradeable components Table 6 summarizes the programmable devices on the RTM and the content that can be upgraded The RTM upgrades can be performed from the CPM s CPU The upgradeable content for the RTM is included in ...

Страница 28: ...5 Components and Subsystems 28 ...

Страница 29: ...g water per kg dry air Storage 5 to 90 RH non condensing at 40 C but not to exceed 0 024 kg water per kg dry air Short term storagea 5 to 95 RH non condensing at 40 C but not to exceed 0 024 kg water per kg dry air Altitude Operating Up to 1800 meters 5 905 feet 55 C 1800 meters up to 4000 meters 13 123 feet derated linearly to 45 C Shock drop Unpacked Free fall corners and edges 0 to 10 kg 100 mm...

Страница 30: ...0950 1 Safety for Information Technology Equipment EU Conformance with the low voltage directive and CB report with group deviations EN 60950 1 Safety for Information Technology Equipment Other CB report including all national deviations IEC 60950 1 Safety for Information Technology Equipment Table 9 Mechanical specifications Characteristic Value RTM dimensions with no SFP modules installed Approx...

Страница 31: ...ng FCC Part 15 Class A 6 db EN 55022 1998 Class A 6 db Note Testing required to 12 GHz Conducted Emissions DC Power Port Operating EN 300 386 Class A 6 dB Note The objective is for the combination of CPM and RTM to meet Class B limits with the chassis PEM filtering removed Conducted Emissions Telecommunications ports Operating EN 300 386 Class A 6 dB Shall be performed on copper SFP interface Obje...

Страница 32: ...power port host chassis 0 5 kV Performance criteria B Conducted Operating EN 61000 4 6 0 15 80 MHz 3 vrms 0 01 30 MHz GR 1089 DC power host chassis copper SFP interface Objective to also evaluate management FE and serial ports Performance criteria A Magnetic field immunity Operating NEN 61000 4 8 50 Hz 1 A m Performance criteria A Immunity Characteristic State Standard and criteria Table 11 RTM po...

Страница 33: ...50 voltage current and or power Ground fixed controlled environment with an environmental adjustment factor equal to 1 0 General assumptions Component failure rates are constant Board to system interconnects are included within estimates A hard disk drive is not included in estimates Non electrical components screws mechanical latches labels covers etc are not included in estimates General notes M...

Страница 34: ...A Specifications 34 ...

Страница 35: ... 0x04 0x21 Reserve Device SDR Repository S E 0x04 0x22 Get Sensor Reading Factors S E 0x04 0x23 Set Sensor Hysteresis S E 0x04 0x24 Get Sensor Hysteresis S E 0x04 0x25 Set Sensor Thresholds S E 0x04 0x26 Get Sensor Thresholds S E 0x04 0x27 Set Sensor Event Enable S E 0x04 0x28 Get Sensor Event Enable S E 0x04 0x29 Get Sensor Event Status S E 0x04 0x2B Get Sensor Reading S E 0x04 0x2D Get Sensor Ty...

Страница 36: ...two possible states only one of which can be active at any given time For example a digital sensor monitoring the power may indicate whether the power is good within an acceptable range or not OEM An OEM sensor is an 8 bit value with its states defined by the manufacturer The reading types of these sensors are sometimes defined as sensor specific Threshold A threshold sensor has a range of 256 val...

Страница 37: ...e Reading Type Normal Reading Alarm level Notes 0 Hot Swap Module Hot Swap Sensor Specific Discrete N A N A Contains module hot swap information as defined in the AMC 0 Specification 1 3 3V MP Voltage Threshold 3 30 Minor Major Critical This sensor measures voltage in Volts Hysteresis 0 05V Default Thresholds LNR LC LNC UNC UC UNR 0 00 3 10 3 15 3 45 3 50 3 60 2 12V Voltage Threshold 12 00 Minor M...

Страница 38: ... voltage in Volts Hysteresis 0 05V Default Thresholds LNR LC LNC UNC UC UNR 0 00 3 10 3 15 3 45 3 50 3 60 9 1 8V Voltage Threshold 1 80 Minor Major Critical This sensor measures voltage in Volts Hysteresis 0 02V Default Thresholds LNR LC LNC UNC UC UNR 0 00 1 70 1 71 1 89 1 90 2 00 10 1 2V Voltage Threshold 1 20 Minor Major Critical This sensor measures voltage in Volts Hysteresis 0 02V Default Th...