A
Specifications
32
Power consumption
Fast transient/burst
Operating
EN 61000-4-4
0.5 kV, 5/50 ns, 5 kHz repetition frequency
DC power (host chassis), copper SFP interface. Objective to also
evaluate management FE and serial ports.
Performance criteria B
Surge voltages
Operating
EN 61000-4-5 (CWG - 1.2/50 µs or 8/20 µs)
Data ports (copper SFP interface. Objective to also evaluate
management FE and serial ports) - 1 kV.
DC power port (host chassis) - 0.5 kV
Performance criteria B
Conducted
Operating
EN 61000-4-6, 0.15 - 80 MHz, 3 vrms
0.01 - 30 MHz, GR 1089
DC power (host chassis), copper SFP interface. Objective to also
evaluate management FE and serial ports.
Performance criteria A
Magnetic field immunity
Operating
NEN 61000-4-8 — 50 Hz / 1 A/m
Performance criteria A
Immunity
Characteristic
State
Standard and criteria
Table 11. RTM power consumption
Product
Maximum power consumption
measured at 25
°
C
RTM with two optical SFP transceivers, using the onboard and AMC hard
disk drives, along with the hard disk drives on another RTM/CPM pair
16.2 W