B
IPMI Commands and Managed Sensors
38
5
Version
Change
Version
Change
Sensor
Specific
Discrete
N/A
N/A
Reports version changes as defined in the IPMI v2.0
specification
6
SAS1064E
Temp
Temp
Threshold
25
Minor,
Major,
Critical
This sensor measures temperature in °C
Hysteresis: 2°C
Default Thresholds
LNR
LC
LNC
UNC
UC
UNR
-10
-5
0
80
90
100
7
+5V
Voltage
Threshold
5.00
Minor,
Major,
Critical
This sensor measures voltage in Volts
Hysteresis: 0.05V
Default Thresholds
LNR
LC
LNC
UNC
UC
UNR
0.00
4.75
4.78
5.22
5.25
5.50
8
+3.3V
Voltage
Threshold
3.30
Minor,
Major,
Critical
This sensor measures voltage in Volts
Hysteresis: 0.05V
Default Thresholds
LNR
LC
LNC
UNC
UC
UNR
0.00
3.10
3.15
3.45
3.50
3.60
9
+1.8V
Voltage
Threshold
1.80
Minor,
Major,
Critical
This sensor measures voltage in Volts
Hysteresis: 0.02V
Default Thresholds
LNR
LC
LNC
UNC
UC
UNR
0.00
1.70
1.71
1.89
1.90
2.00
10
+1.2V
Voltage
Threshold
1.20
Minor,
Major,
Critical
This sensor measures voltage in Volts
Hysteresis: 0.02V
Default Thresholds
LNR
LC
LNC
UNC
UC
UNR
0.00
1.12
1.14
1.26
1.28
1.32
11
MMC Reset
OEM
Sensor
Specific
Discrete
N/A
N/A
Reading Bit Flags
0x01 - Hard reset
0x02 - Cold reset
0x04 - Warm reset
0x08 - External reset
0x10 - JTAG reset
0x20 - Power fail reset
0x40 - Software reset
0x80 - MMC watchdog reset
0x100 - First boot
Table 15. Managed sensors
Number
Name
Type
Reading
Type
Normal
Reading
Alarm
level
Notes
Содержание ATCA-5400 RTM
Страница 1: ...www radisys com PROMENTUM REAR TRANSITION MODULE REFERENCE ATCA 5400 007 03301 0000 August 2009 ...
Страница 8: ...8 ...
Страница 24: ...4 LEDs and External Interfaces 24 ...
Страница 28: ...5 Components and Subsystems 28 ...
Страница 34: ...A Specifications 34 ...