Page 9
D# REXShunt Only?
Default:
No
Selections:
Yes or No
Use this program item to disable the strike, but still activate the programmed
shunt time upon a Request to Exit an area.
Yes -------- Programmed shunt time will activate so door can be manually
opened.
No ---------- Request to Exit (REX) automatically activates the programmed
strike and shunt time.
Application Tip: Use this parameter when a user can open a door manually
without relying on a token/card to activate the strike (such as with a “push bar”).
NOTE: When REXShunt Only is “Yes,” Request To Exit events are not logged,
reported, or printed.