ACCESS
Door Profile
32207C 3/97
D9210B Program Entry Guide
© 1996 Radionics
Page 5
D# Door Point
Default:
Blank
Selections:
Blank, 1 - 127, 129 - 247
Enter the point number that will be assigned to this door. This point cannot be
used for any other point assignments.
1 - 127, 129 - 247 ----- The point number assigned to this door. Points 128 and
248 are reserved by the panel for internal use.
Blank -------------------- There is no point number assigned to this door.
Troubleshooting Tip: IMPORTANT! When assigning points 1-8 (panel
zones), the end-of-line resistors must be removed from the panel. Failure to do
so will result in Extra Point trouble conditions upon reboot.
D# Interlock Point
Default:
Blank
Selections:
Blank, 1 - 127, 129 - 247
Enter the interlock point number. This point, when faulted, will prevent the door
controller from allowing access upon a valid ID read or door request.
Do not assign this point to another door point. You may assign it to another
controller thereby having one interlock point prevent multiple controllers from
activating.
1 - 127, 129 - 247 ----- The point number assigned to the interlock point. Points
128 and 248 are reserved by the panel for internal use.
Blank -------------------- There is no point number assigned to the interlock point.
Programming Tip: CAUTION. The interlock point will be considered in a
normal state if it is bypassed, swinger bypassed, or forced armed. This will
result in normal operation of access even if the door is left open.
D# Auto Door?
Default:
No
Selections:
Yes or No
Use this program item to unlock the door (latched shunt and strike)
automatically when the entry area is disarmed and return the door to the locked
state (ready to read IDs) when the area is armed.
Yes -------- When the area assigned in D# Entry Area # is disarmed, the door
will be in the Hold Open Door state automatically. When that area
is armed, the door will return to the Locked Door state.
No ---------- Door state will not be affected by the armed state of the area.
Application Note: The Hold Open Door state cannot be overridden manually.
Programming Tip: Perimeter Armed is considered an armed state for this
function.