![background image](http://html.mh-extra.com/html/radionics/d9210b/d9210b_program-entry-manual_780454011.webp)
ACCESS
Event Profile
32207C 3/97
D9210B Program Entry Guide
© 1996 Radionics
Page 11
D# Enter Request?
Default:
No
Selections:
Yes or No
This program item determines if Request to Enter (RTE) events are sent to the
panel for processing memory, printing, and remote reporting.
Yes -------- A
DOOR REQUEST TO ENTER
event from this door controller is sent to
the panel for processing.
No ---------- A
DOOR REQUEST TO ENTER
event from this door controller is not
sent to the panel for processing.
Programming Tip: RTE events require D# Access Granted to be
programmed YES.
D# Exit Request?
Default:
No
Selections:
Yes or No
This program item determines if Request to Exit (REX) events are sent to the
panel for processing memory, printing, and remote reporting.
Yes -------- A
DOOR REQUEST TO EXIT
event from this door controller is sent to
the panel for processing.
No ---------- A
DOOR REQUEST TO EXIT
event from this door controller is not sent
to the panel for processing.
Programming Tip: REX events require D# Access Granted to be
programmed YES.