Page
11
of
29
©
2019 Radiocrafts AS
RC1180-MPC1/RC1701HP-MPC1 User Manual (rev. 1.1)
RC1180-MPC1
USER MANUAL RC1701HP-MPC1
Appendix A
Configuration commands
Command
Details
Comments
ASCII
hex
‘M’
0x4D
Memory Configuration
This command is used to change configuration parameters in
NVM.
When you have sent the M-command you enter memory
configuration mode. Multiple pairs of A Data can be
sent before you send the 0xFF command to exit Memory
configuration mode.
Argument
Options
Returns
Address
See
Error! Reference
source not found.
for
overview of configuration
parameters available.
(none)
Data
Configuration Parameter
value
(none)
Address
(optional)
(none)
Data
(optional)
(none)
Exit
0xFF
Prompt (>)
Caution!
The M-
command is writing to
NVM/flash, and this
operation must not be
interrupted by for
example a reset or
powercycle. Interrupting
the NVM update may
leave the configuration
memory corrupted.
Caution!
The NVM also
has a limited number of
writecycles (10000x), and
we therefore strongly
recommend that you do
not use the M-command
“in field”, only when
configuring and testing
your module as part of
your production test.
‘X’
0x58
Exit
This command exits configuration mode and sets module back
in idle mode, ready to send/receive data packets.
Argument
Options
Returns
(none)
(none)
(none)
‘Y’
0x59
Memory Read One Byte
Argument
Options
Returns
Address
See
Error! Reference
source not found.
for
overview of configuration
memory
1 byte value
for given
address
+Prompt (>)
‘Z’
0x5A
Sleep
This command is used to exit configuration mode and at the
same time set module in sleep mode. To exit sleep mode (go to
IDLE again)
– send 0xFF on UART RXD.
Argument
Options
Returns
(none)
(none)
(none)