Configuration Memory
Table 3
– Configuration Memory
Parameter
Addr
(hex)
R
C
1
1
x
x
R
C
1
7
x
x
H
P
Argument range
Comment
Default/
Factory Setting
Radio Configuration
RF_CHANNEL
0x00
✘
✔
RC11xx: N.A.
RC17xxHP: 1-41
N mode only, see RC17xxHP datasheet for
details.
RC11xx: N.A.
RC17xxHP: 0x03
RF_POWER
0x01
✔
✔
1-5
Default RF output power [dBm]
RC11xx
RC17xxHP
1
0x01
-20
+14
2
0x02
-10
+17
3
0x03
0
+20
4
0x04
+5
+24
5
0x05
+10
+27
0x05
DATA_RATE
0x02
✘
✔
RC17xxHP: 1-2,5
RF data rate
RC11xx
RC17xxHP
1
0x01
-
2.4kbps
2
0x02
-
4.8kbps
5
0x05
-
6.4kbps
RC11xx: N.A.
RC17xxHP: 0x01
MBUS_MODE
0x03
✔
✔
RC11xx: 1,3,9
RC17xxHP: 17
RC11xx
RC17xxHP
1
0x01
T1
-
3
0x03
S1
-
9
0x09
C1*)
17
0x11
-
N1
*) Datarate accuracy not within limits given in
Wireless M-Bus standard. Packets can be
received by RC11xx-MBUS3 modules.
RC11xx: 0x01
RC17xxHP: 0x11
Device Configuration
PREAMBLE_LENGTH
0x0A
✘
✔
0-2
DLL Frame format A or B
RC11xx
RC17xxHP
0
0x00
-
FFA
2
0x02
-
FFB
RC11xx: 0x00
RC17xxHP: 0x00
PACKET_TIMEOUT
0x10
✔
✔
0x01 – 0xFF
OTA configuration listening window after TX
0xCC: 2s
TX_INTERVAL_H/L
0x2D
0x2E
✔
✔
0x0001-0xFFFF
Interval (s) = TX_INTERVAL*0.9s
Default 5 seconds.
0x0006
M_ID1
0x19
✔
✔
0x00-0xFF
Manufacturer ID, first byte
0x0C
M_ID2
0x1A
✔
✔
0x00-0xFF
Manufacturer ID, second byte
0xAE
U_ID1
0x1B
✔
✔
0x00-0xFF
Unique ID, first byte
0x12
U_ID2
0x1C
✔
✔
0x00-0xFF
Unique ID, second byte
0x34
U_ID3
0x1D
✔
✔
0x00-0xFF
Unique ID, third byte
0x56
U_ID4
0x1E
✔
✔
0x00-0xFF
Unique ID, fourth byte
0x78