REGULATION INSTRUCTIONS
CONDENSING BOILOES WITH STORAGE - TG05A095.A0306
37
◄
PARAMETER N° 4 – PUMP MODE ON CENTRAL
HEATING
PHASE
7. Use
(
▲
) and (
▼
) buttons to modify the value of the
parameter:
00 = STANDARD (3 ‘ OVERRUN)
01 = ALWAYS RUNNING
(to be activated
ONLY FOR SYSTEM BOILERS
);
8.
Press and release the service (
S
) button to confirm your
choice. Number 4 will appear on the display;
9.
If you have to modify some other parameter, follow the 4 – 5
steps (p. 35), then go to the specific procedure for
that
parameter, otherwise switch off and on the appliance to
register the modifications.
◄
PARAMETER N° 5 – WATER HAMMER EFFECT
PREVENCTION
7. Use
(
▲
) and (
▼
) buttons to modify the value of the
parameter:
00 = OFF
01 = ON: 2’’ delay on D.H.W. start;
8.
Press and release the service (
S
) button to confirm your
choice. Number 5 will appear on the display;
9.
If you have to modify some other parameter, follow the 4 – 5
steps (p. 35), then go to the specific procedure for
that
parameter, otherwise switch off and on the appliance to
register the modifications.
◄
PARAMETER N° 6 – CENTRAL HEATING TIMER
7. Use
(
▲
) and (
▼
) buttons to modify the value of the
parameter
between:
00 = 0’’
99 = 99 x 5’’ = 450’’ = 7.5’
Default value is set to 36 = 180’’ = 3’.
8.
Press and release the service (
S
) button to confirm your
choice. Number 6 will appear on the display;
9.
If you have to modify some other parameter, follow the 4 – 5
steps (p. 35), then go to the specific procedure for
that
parameter, otherwise switch off and on the appliance to
register the modifications.
S
S
00
4
5
01
S
S
S
36
S
6