REGULATION INSTRUCTIONS
CONDENSING BOILOES WITH STORAGE - TG05A095.A0306
36
S
S
1
2
01
S
S
S
00
S
3
02
5.2.2 Parameters settings
To enter the parameters menu, follow the procedure shown at page n° 35 (steps 1-6).
◄
PARAMETER N° 1 – TYPE OF BOILER
7.
Use (
▲
) and (
▼
) buttons to modify the value of the
parameter:
00 = Instantaneous boiler;
01 = Storage boiler;
02 = ‘Storage comfort’ boiler. With this option you’ll
have stored water with 7° higher temperature;
8.
Press and release the service (
S
) button to confirm
your choice. Number 1 will appear on the display;
9.
If you have to modify some other parameter, follow
the 4 – 5 steps (p. 35), then go to the specific procedure
for that parameter, otherwise switch off and on the
appliance to register the modifications.
◄
PARAMETER N° 2 – KIND OF GAS SUPPLY
7. Use
(
▲
) and (
▼
) buttons to modify the value of the
parameter:
00 = Natural gas
01 = LPG;
8.
Press and release the service (
S
) button to confirm
your choice. Number 2 will appear on the display;
9.
If you have to modify some other parameter, follow
the 4 – 5 steps (p. 35), then go to the specific procedure
for that parameter, otherwise switch off and on the
appliance to register the modifications.
◄
PARAMETER N° 3 – CENTRAL HEATING
TEMPERATURE
RANGE
7. Use
(
▲
) and (
▼
) buttons to modify the value of the
parameter:
00 = STANDARD (30 – 80 °C)
01 = REDUCED (25 – 40 °C) for floor systems;
8.
Press and release the service (
S
) button to confirm
your choice. Number 3 will appear on the display;
9.
If you have to modify some other parameter, follow
the 4 – 5 steps (p. 35), then go to the specific procedure
for that parameter, otherwise switch off and on the
appliance to register the modifications.