![Radiant RBC 24 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/radiant/rbc-24/rbc-24_installation-use-and-maintenance-manual_3274011032.webp)
32
RBS 24 - RAD - ING - Manual - 1709.1_MIAB2013_R7
2 T
abella par
ametri_MIAB2013_firm.H070C_EN
2. FIRST START-UP
SUPPOR
T
C
ENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P07
ANTI-WATER HAMMER SELECTION
BY ACTIVATING THIS FUNCTION, THE DOMESTIC
CONTACT IS DELAYED FOR A TIME EQUAL TO THAT
SET.
000 - 003
000 = DISABLED
THE VALUE IS EXPRESSED IN SECONDS
(PRE-SET TO 2 SECONDS)
P08
HEATING START DELAY
USING THIS SETTING, THE BOILER START DELAY
TIME CAN BE SET, IN HEATING PHASE, WHEN THE
AMBIENT THERMOSTAT CONTACT IS CLOSED.
000-199
000 = DISABLED (PRE-SET BY DEFAULT)
THE VALUE IS EXPRESSED IN SECONDS
P09
SETTING THE HEATING TEMPERATURE
IN CASE OF DIRECT SUPPLY, BY A GENERATOR, OF A
LOW TEMPERATURE SYSTEM, INSTALL A SECURITY
THERMOSTAT ON THE DELIVERY WHICH INTERRUPTS
THE OPERATION OF THE GENERATOR IN CASE OF
HIGH DELIVERY TEMPERATURE. THE COMPANY IS
NOT HELD LIABLE FOR RESULTING DAMAGES TO
PERSONS OR THINGS DUE TO THE NON-OBSERVANCE
OF SUCH INDICATION.
000 - 001
000 = STANDARD (30-80 °C)
(SET BY DEFAULT)
001 = REDUCED (25-45 °C) FOR FLOOR
SYSTEMS
P10
POST-VENTILATION TIMER
THIS PARAMETER SETS HOW LONG THE FAN
OPERATES AFTER THE BURNER HAS SWITCHED OFF.
003-200
VALUE EXPRESSED IN MULTIPLES OF 3
SECONDS
(PRE-SET TO 4×3=12 SECONDS)
P11
BOILER TYPE SELECTION
000 - 003
000 = BITHERMAL
001 = MONOTHERMAL INSTANT
002 = HEATING ONLY
003 = ACCUMULATION