37
EN
21. Removing the belt in the event of unit failure
In the event that the RolloTron Standard unit fails and the
motor no longer runs, you can use the disengaging bracket
provided in order to fully remove the belt from the belt
winder unit, without the need for cutting it.
1.
Remove the mains plug from the socket.
2.
Dismantle the RolloTron Standard as previously demon-
strated on page 35.
3.
Release the drive with the help of the supplied disengag-
ing bracket.
4.
Maintain pressure on the disengaging bracket and pull
the belt out of the RolloTron Standard as far as possible.
RolloTron
Standard
RolloTron
Standard
Plus
i
Drive release
Storage bay
Drive release
WARNING!
There is a risk of injury as the roller shutters may slam
shut or fall in an uncontrolled manner.
◆
Secure the roller shutters from falling.
◆
Hold on to the belt tightly to stop the roller shutters
from slamming shut or falling in an uncontrolled
manner.
◆
Get a second person to help you unlatch the unit.
5.
Release the belt from the fastening hook and pull it out
completely from the RolloTron Standard.
6.
Place the disengaging bracket back in its holder.