16. Automatic twilight function; brief description
i
The automatic twilight function causes the roller shutters
to close automatically under the following conditions:
◆
If the automatic twilight function is activated.
◆
If twilight is detected for a minimum of 15 seconds.
◆
If the light sensor has been mounted and plugged
into the RolloTron Standard.
Automatic lowering
At twilight, the roller shutters will lower to the lower end
point after approx. 15 seconds. The roller shutters will
open again once the configured opening time is reached
or in the event of a manual UP command.
The required twilight limit is configurable.
If the roller shutters are to be lowered as a result of the
automatic twilight function, then you must either set-
ting the closing time to a time after dusk (see example).
If an automatic closing command is given before twilight
triggers, then the automatic twilight function will not be
executed.
Example
1
/ 2
Automatic closing time:
23:00 hours / 19:30 hours
Onset of dusk:
20:30 hours / 20:30 hours
Your roller shutters will
close automatically at:
20:30 hours / 19:30 hours