5.3.1 Transmitters configuration
The elements of the first six lines are:
1 ... 6
Transmitter number
When present, indicates the ON status
The presence of this icon indicates RF “Power good”
The presence of this icon indicates the presence in the
SCM6/1 of the telemetry board related to the transmitter and
its good communication with the system board
1
Priority level assigned to the transmitter. This parameter is
used by the changeover management algorythm to determine
wich transmitter has to be suInterlocktituted by the reserve
transmitter if more than one transmitter are faulty at the same
time.
On/Off
Status of the transmitter. This item can be used as a switch: in
configuration or maintenance mode (see below), pushing the
encoder when the cursor is on this item will toggle the status
of the transmitter, sending the relevant TCs. If, for any reason,
the command is not performed by the transmitter, the actual
status of the transmitter will be shown.
Air/Load
Status of the switch of the transmitter. This item can be used
as a switch: in configuration or maintenance mode (see
below), pushing the encoder when the cursor is on this item
will change the status of the switch (Position 1 to Position 2 or
vice versa), sending the relevant TCs. If, for any reason, the
command is not finalized, the actual status of the switch will be
shown.
Enabl./Disabl.
Configuration of the transmitter with reference to the
automatism. If there is a power fault in a transmitter that is
currently disabled, the automatism will not take it into account
for a permutation. The transmitter is considered enabled if it
is not in “Local” mode (e.g. for maintenance) and if it’s set as
enabled in the SCM6/1 configuraration.
To modify the configuration of this setting on the SCM6/1, push
the encoder when the cursor is on this item: the indication
Enabl. or Disabl. will be shown, respectively meaning that the
transmitter shall be considered enabled or not by the SCM6/1.
Содержание SCM6/1
Страница 1: ...SCM6 1 SCM6 1 USER MANUAL VOLUME1 Manufactured by R V R ELETTRONICA Italy ...
Страница 4: ...ii User Manual Rev 2 0 28 10 22 SCM6 1 ELETTRONICA ...
Страница 6: ...iv User Manual Rev 2 0 28 10 22 SCM6 1 ELETTRONICA This page was intentionally left blank ...
Страница 46: ...40 40 User Manual Rev 2 0 29 11 22 SCM6 1 ELETTRONICA This page was intentionally left blank ...