Power
Good
Interlock
+ 24V
TX Example
SCM6/1
(or any changeover system)
+ 24V
TX ON
TX OFF
Figure 6-2
In a real installation, TCs and TSs are exchanged between the SCM6/1 and all
the other devices in the transmission system (see the details in the following
paragraphs). In general, TSs and TCs are constituted by dry contacts that are
closed or opened by the generator of the information, and that are energized by
the user of the information.
An example of the set of TCs and TSs exchanged between the SCM6/1 and a
transmitter Is given in figure 4-3.
6.1.1 Links with the main transmitters
6.1.1.1 Signalizations to N+1
1 Transmitted power fault: when the fault occurs the Interlock is open,
2 Local mode: when the transmitter is in local mode the Interlock is closed,
3 On transmitter: when the transmitter is in On the Interlock is closed, These
Interlocks are polarized for the + 24 of the N+1 (pin 16)
6.1.1.2 Telecontrols
1 Transmitter power on: On command of the main transmitter (TX 1 to TX6)
2 Transmitter shutdown: Off command of the main transmitter (TX 1 to TX 6)