6.1.2 Connections with emergency transmitter
6.1.2.1 Telesignalizations
1 Off : closing the interlock means that the transmitter is actually stopped,
2 On : closing the interlock means that the transmitter is actually On,
3 Transmitter fault: the closing of the interlock means that the transmitter is either
in power alarm, or stopped on fault
4 Local Mode : closing the interlock means that the transmitter is in local mode
5 Transmitter Configuration (TX 1 to TX 6): closing one of the interlocks signals
enable the configuration of the transmitter.
These telesignalizations are obtained by permanent interlocks opening/closing via
a TS Common polarized by the SCM6/1.
6.1.2.2 Telecontrols
1 On transmitter,
2 Off transmitter,
3 Transmitter Configuration (TX 1 to TX 6)
These telecontrols are obtained by closing a dry interlock by the RVR system,
from the TC common supplied by the reserve transmitter.
6.1.2.3 Others
1 The interlock is connected (2 points: open = fault)
6.1.3 TC/TS Signals
6.1.3.1 Telesignalizations
1 On Position 2: copy of the TC On acknowledgment on R&S Transmitter,
2 Local Position 2: active when R&S transmitter is in local mode,
3 Mode 1: copy of the TC Mode 1 acknowledgment (normal)
4 Mode reserve: copy of the TC Mode 2 acknowledgment (emergency)
5 Fault N+1: active when fault self-diagnosis,
6 Manual N+1: active when automation N+1 is disengaged,
These telesignalizations, in up to 6 copies, are generated by the RVR system and
are maintained (permanent).
Содержание SCM6/1
Страница 1: ...SCM6 1 SCM6 1 USER MANUAL VOLUME1 Manufactured by R V R ELETTRONICA Italy ...
Страница 4: ...ii User Manual Rev 2 0 28 10 22 SCM6 1 ELETTRONICA ...
Страница 6: ...iv User Manual Rev 2 0 28 10 22 SCM6 1 ELETTRONICA This page was intentionally left blank ...
Страница 46: ...40 40 User Manual Rev 2 0 29 11 22 SCM6 1 ELETTRONICA This page was intentionally left blank ...