HC5-10
18 / 34
User Manual
Rev. 1.0 - 26/03/04
To change the values of the thresholds, execute the following procedure:
•
Select the line to modify (UP and DOWN buttons)
•
Push the ENTER button
•
Modify the value of the threshold (UP and DOWN buttons)
•
Push the ENTER button to confirm
The following figure shows an example of configuration for this menu.
In questo esempio, le soglie degli allarmi sono:
•
PwrGd 1
8000 W
(80% X 10000 W)
•
PwrGd2
5000 W
(50% X 10000 W)
•
RflWar
700 W
(70% X 1000 W)
5.3.5
Alarms Menu (Alm)
This screen gives to the user information regarding the status of the protection system
included in the hybrid coupler.
It is constituted by a certain number of lines, each containing the name of a variable
controlled by the system and the kind of intervention that is undertaken by the system
in case the parameter surpasses its limit.
The latter can be of the kind: X - (Y), Wait, or Dis. (Disabled).
The aspect of this multi-line screen is the following (only two lines at a time are visible,
use the UP and DOWN buttons to scroll):