HC5-10
24 / 34
User Manual
Rev. 1.0 - 26/03/04
1
14
6.3
Connectors Description
6.3.1
Telemetry Connector
Type: DB25 Female
1
Rej Pwr T
Ana Out
Unbalanced power
2
Ch4 T
Disabled
3
GND
GND
4
Rfl Pwr T
Ana Out
Reflected power
5
OC_EXC T
Dig Out OC
Active when interlock is active
6
OC_SET4 T
Dig Out OC
Active when SET4 threshold surpassed
7
GND
GND
8
IN_ON T
Dig In
“ON” command
9
OC_SET1 T
Dig Out OC
Active when SET1 threshold surpassed
10
OC_WAIT T
Dig Out OC
Active for “Wait” alarm presence
11
IN_RST T
Dig In
“Alarms Reset”
12
OC_OFF T
Dig Out OC
Active when OFF
13
IN_INH T
Dig In
Keep at GND potential to inhibit
14
TEMP T
Ana Out
Temperature
15
Ch_5 SDA
Disabled
16
FWD PWR T
Ana Out
Forward power
17
OC_FAULT T
Dig Out OC
Active for “Fault” Alarm presence
18
OC_SET3 T
Dig Out OC
Active when SET3 threshold surpassed
19
INP_PWR SCL
Disabled
Input power
20
IN_OFF T
Dig In
“OFF” command
21
GND
GND
22
OC_SET2 T
Dig Out OC
Active when SET2 threshold surpassed
23
OC_LOC T
Dig Out OC
Active when in local mode
24
VNS T
+12 Vcc
Unregulated voltage
25
OC_ON T
Dig Out OC
Active when ON
Notes:
•
To give a command to the HC5 (ON, OFF, Reset), bind the relative pin to ground
for approx 500 ms.
•
OC output (Open Collector) are “Active” when conducing.
6.3.2
RS232 Connector
Type: DB9 Female
1
N.C.
2
TXD
3
RXD
4
Internally connected to 7 and 8
5
GND
6
N.C.
7
Internally connected to 4 and 8
8
Internally connected to 4 and 7
9
N.C.
1