MQVL48 / MQVLB48
Clearance to Combustibles
Front (Furniture, etc. from glass)
36” [92cm]
Side (Furniture, etc. from glass)
36” [92cm]
Side (from Stand-offs of VLB48 or Corner Kit)
0” [0cm]
Back (from Stand-offs)
0” [0cm]
Floor
0” [0cm]
Minimum Ceiling Height (from bottom of fireplace)
76” [193cm]
Top (from Stand-offs)
0” [0cm]
Top of 90° Bend in minimum Enclosure of 76”
14-1/2” [36.8cm]
Top of 90° Bend in Enclosure over 76”
4” [10.2cm]
VENTING SYSTEMS
Top of Horizontal Pipe
1/1/2” [3.8cm]
Side & Bottom of Horizontal Pipe
1” [2.5cm] All Vent Systems
Vertical Vent Pipe
1” [2.5cm] All Vent Systems
SIDE VIEW (MQVLB48 SHOWN)
No Framing on
Top
Sides
of fireplace
for MQVL48 Single
Side Units
Top opening of
Chase must be
within
2”
of
Enclosure Top
(
Min 151 sq. in
.)
⚠
NOTE
If using insulation in
vented chase (i.e. for
outside wall), wall board /
drywall is required to
support all insulation.
Vented chase must be
clean and free of all
debris (i.e. loose
insulation, pieces of
wood, etc.).
*
THIS AREA
MUST BE OPEN
MIN 480 Sq. In.
Bottom Air Opening
Options – Min 84 sq. in.
28-1/2”
(55” TV)
CEILING
3/4”
2” MAX
76”
MIN
CEILING
76”
MIN
ENCLOSURE
57-1/2”
MIN
14-1/2”
4-9/16”
Opening must not be
blocked by floor covering
18