Warnings, Installations and Operations 

Installation Regulations 

This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current 
CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1-

 

NFPA 54 when installed in the United States. 

This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the 
current CSA C22.1 Canadian Electrical Code or with the National Electrical Code; ANSI/NFPA 70 when installed in the United States. 

In the U.S.A

Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-Decorative).

 

 

 

WARNING

 

FOR SAFE INSTALLATION AND OPERATION OF YOUR GAS FIREPLACE PLEASE NOTE THE FOLLOWING: 

1.  Do not clean when the glass is hot.  
2.  Do not use abrasive cleaners. 

3.  Using a substitute glass will void all product 

warranties. 

4.  For safe operation, glass doors must be 

closed. 

5.  When purging the gas line, the glass front 

must be removed. 

6.  Do not strike or abuse glass. Take care to 

avoid breakage. 

7.  Do not alter gas orifice. 

8.  No substitute materials may be used other 

than factory supplied components. 

9.  This appliance gives off high temperatures and should be located out of heavy traffic areas and away from furniture and 

draperies. 

10.  Children and adults should be alerted to the hazards of the high surface temperatures of this appliance and should stay 

away to avoid burns or ignition of clothing. 

11.  Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children 

and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals 
in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and 
other at risk individuals out of the room and away from hot surfaces. 

12.  Under no circumstances should any solid fuels (wood, paper) be used in this appliance. 
13.  Under no circumstances should this appliance be modified. Any parts that have to be removed for servicing should be 

replaced prior to operating this appliance. 

14.  Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance. 

15.  Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at 

least annually by a professional service person. More frequent cleaning may be required due to excessive lint from 
carpeting, bedding material, et cetera. It is imperative that control compartments, burners and circulating air passageways of 
the appliance be kept clean. Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit. 

16.  Clothing or other flammable material should not be placed on or near the appliance. This appliance should not be used as a 

drying rack for clothing nor should Christmas stockings or decorations be hung from it. 

17.  Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater 

and to replace any part of the control system and any gas control which has been under water. 

18.  Do not operate appliance unless completely installed as per installation instructions. 
19.  Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this 

appliance may result in property damage or personal injury. 

20.  Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a 

licensed or qualified service person. 

21.  The front of the fireplace gives off high temperatures that could ignite combustible material which is kept close to the front of 

the unit. 

22.  Ensure that power to the Fireplace is turned off before servicing. 
23.  Do not operate this Fireplace without the glass front or with a broken glass. 
24.  Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the 

owner’s information manual provided with this appliance. For assistance or additional information consult a qualified 
installer, service agency, or the gas supplier. 

25.  Operation of this appliance when not connected to a properly installed and maintained venting system or tampering with the 

blocked vent shutoff system can result in carbon monoxide (CO) poisoning and possible death.

 

26.  This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be 

plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. 

 

WARNING

 

HOT GLASS

 WILL 

CAUSE BURNS 

DO NOT TOUCH

 GLASS 

UNTIL COOLED. 

NEVER

 ALLOW CHILDREN

TO TOUCH GLASS. 

 

Содержание Kingsman Fireplaces FDV350

Страница 1: ...Propane Horizontal installations the venting must be a minimum of one foot vertical off the flue before going horizontal Installation Instructions Model Number FDV350 Free Standing Direct Vent Gas St...

Страница 2: ...the installations e g marble tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove for a mini...

Страница 3: ...Installation of brick panel kit 12 Log assembly 13 Optional fan kit installation 14 Millivolt system lighting burner control 15 Vent termination 16 General venting information 17 Vent pipe assembly 1...

Страница 4: ...ED USING THE B VENT CONVERTER CANNOT BE INSTALLED IN A MANUFACTURED MOBILE HOME Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrica...

Страница 5: ...the appliance 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent...

Страница 6: ...in the living area outside the bedroom s The carbon monoxide detector shall comply with NFPA 720 B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and s...

Страница 7: ...l with no additional floor protection being required This unit has been tested in a Alcove the minimum size of Alcove is Depth 30 Height 55 5 Width 52 5 THE FOLLOWING MINIMUM DISTANCES TO COMBUSTIBLES...

Страница 8: ...n excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at t...

Страница 9: ...eries Children and adults should be alerted to the hazards of high surface temperatures of this appliance and should stay away to avoid burns or ignition of clothing Control compartments burners and a...

Страница 10: ...er cardboard coal be used in this appliance NOTE it is normal for your gas stove to give off some odour the first time it is burned This is due to the curing of the paint and any undetected oil from t...

Страница 11: ...the Door Frame to the unit reverse the above steps GENERAL GLASS INFORMATION GLASS CLEANING It will be necessary to clean the glass periodically During start up condensation which is normal forms on t...

Страница 12: ...right of panel tilt the top panel towards you slightly and pull your right hand towards you slightly and place panel onto the rear of the firebox NOTE TAKE CARE NOT TO DAMAGE PILOT ASSEMBLY WHEN PLACI...

Страница 13: ...side of the log mounting pan as shown in the picture Fig 5 Log C has to be lowered into position just behind logs A and B Log C has an area notched out of the rear of it to fit over rear positioning b...

Страница 14: ...kwise Use the set screw on the side of the variable speed control to increase or decrease the minimum fan speed It may be desirable to lower minimum fan speed to decrease the sound level created by th...

Страница 15: ...pilot screw to provide proper sized flame Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire Size Max Length 14 GA 100 FT 16 GA 64 FT 18 GA 40 FT 20 GA 25 FT 22 GA...

Страница 16: ...8 inches 45cm N Clearance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For additional requirements check local codes V NOTE Clearances are to the edg...

Страница 17: ...fically approved and LABELED for this stove may be used This appliance is also approved for use with Simpson Duravent Direct Vent system Ameri Vent Direct Vent Pipe System ICC Excel Direct Metal Fab S...

Страница 18: ...mum stove performance HOW TO USE THE VENT TABLE 1 Determine the height of the system and the number of elbows required 2 Use the Venting Chart to determine the maximum horizontal distance allowed Tota...

Страница 19: ...ature sealant MIL PAC SEALANT IS RECOMMENDED to the pipe and secure it with the 4 screws If two pieces of 4 flex pipe are to be joined the joint must be siliconed and secured with four screws Before j...

Страница 20: ...only time this may be unavoidable is when installing the vent terminal Note Do not remove or move spacer springs attached to 4 inner flex pipe these must be used to assure an 1 1 4 air gap between 4...

Страница 21: ...to the top of the horizontal pipe must be maintained Maximum vertical height of system should not exceed 40 feet Spacer springs to be installed on 4 flex pipe every 3 ft on vertical runs On 45 elbows...

Страница 22: ...y seated Screw the Converter to the stove with 2 of the 4 screws supplied 3 Place the decorative collar around the adapter and screw in place 4 Route the Safety Spill Switch wires down the rear of the...

Страница 23: ...inch single wall or B Vent liquid fuel gas chimney or Flex Gas Liner may be used to adapt existing chimney or liner to stove When installing with B Vent liquid fuel gas chimney install as per B Vent M...

Страница 24: ...Galvanized Pipe 7 Dia x 48 Vertical Installations ZDV4FP8 Flex Pipe 4 Diameter 4 Unexpanded to 8 Expanded ZDV4FP20 Flex Pipe 4 Diameter 10 Unexpanded to 20 Expanded ZDV4FC Flex Connector 4 Diameter ZD...

Страница 25: ...0633 1001 P634SI VALVE NOVA NG Hl LO 0820634 1001 P216SI THEMOCOUPLE 290 216 FOR 713 714 TOP CON PILOT 1001 P069SI ELECTRODE CABLE 915 069 FOR 713 714 TOP CON PILOT 1001 P167SI ORIFICE 30 LP 977 167 F...

Страница 26: ...itch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generator may not be Check generator with millivolt meter Take reading at generat...

Страница 27: ...s other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or a...