This page is only for boilers using an oil burner. If a gas burner is being used, please refer to
page 13 for the proper setup of the burner and gas lines.
8.1 Oil Burner Setup
Beckett
NX
Boiler Model
SG-3
SG-4
Burner Model
NEC 1202 NEC 1202
Firing Rate
0.91
1.22
Insertion Depth
6"
6"
Nozzle
.75 X 60B 1.00 X 60B
Spray Pattern
B
B
Pump Pressure
145 psi
145 psi
Head Type
9-slot
9-slot
Head Position
2.5
4.5
Carlin
Boiler Model
SG-3
SG-4
SG-5
Burner Model
EZ-1
EZ-1
EZ-1
Firing Rate
0.91
1.22
1.52
Insertion Depth
3.5"
3.5"
3.5"
Nozzle
.65 x60
1.00 x 60 1.25 X 60
Spray Pattern
B
B
B
Pump Pressure
175 psi
135 psi
140 psi
Head`
.60/.65
.85/1.00
1.10/1.25
Air Gate
0.9
1.2
1.65
BURNER MANUFACTURER Riello
R-40 Series
Boiler Model
SG-3
SG-4
SG-5
Burner Model
F-5
F-5
F-5
Firing Rate
0.91
1.22
1.52
Insertion Depth
5"
5"
5"
Nozzle
.75 X 60
1.00 x 60 1.25 X 60
Spray Pattern
W
W
W
Pump Pressure
145 psi
145 psi
145 psi
Turbulator
1
3
4
Air Gate
2.5
3
4
BURNER MANUFACTURER
BURNER MANUFACTURER
For Carlin and Beckett burners to qualify for Energy Star, it is necessary to install and automated vent damper to prevent off cycle losses.