Section VII - Problem solving
42
Cause
Remedy
Pump element out of order
Consult Quincy
Ambient temperature too high
Check limitations
Inlet temperature too high
Check limitations
Internal cooling of the element
too low
Check for clogging in suction, discharge or
pressure line.
Check size and length of the installed suction,
discharge or pressure line to lower pressure
drops
Inlet non-return valve is blocked
Consult Quincy
Bearings damaged
Consult Quincy
Motor coupling damaged
Consult Quincy
Low oil level in gearbox
Re-fill gearbox if necessary. Check for possible
leakages.
Fan damaged
Consult Quincy
Gears damaged
Consult Quincy