Section III - Installation
30
When replacing the air intake filter element, the dust may fall into the pump inlet and
resulting damage to the pump. The air intake filter (1) should be installed in a horizontal
position to prevent filtered dust falling into the pump inlet
Safety
The operator must apply all relevant Safety precautions.
Outdoor/altitude operation
The pumps are not designed for outdoor use.
The pumps can only be used in temperatures above 0° C (+32° F). If frost might occur,
the appropriate measures should be taken to avoid damage to the machine and its
ancillary equipment. In this case, consult Quincy.
Also if operating above 1000 m (3300 ft.), consult Quincy.
Moving/lifting
The pump is delivered on a wooden pallet. During transport, the pump is secured to the
pallet using bolts.
Remove the transport fixation bolt before lifting. Lift the pump carefully with a hoist of
appropriate lifting capacity.
The lifting eye (1) provided at the top of the pump for lifting. See figure
below.
Reference
Name
1
Lifting eye