EN
.
58
Parameter no. 101
–
Enable / Disable Endpoint I3 or select the Notification Type and the
Notification Event
Choose whether the Endpoint I3 is disabled (and not shown on the UI) or enabled (and
displayed on the UI). By enabling this endpoint (setting it to be either a notification sensor or a
binary sensor), the user also selects a Notification Type and a Notification Event for which
notification reports will be sent (in case the endpoint is configured as a notification sensor).
Endpoint device type selection:
-notification sensor (1 - 6):
GENERIC_TYPE_SENSOR_NOTIFICATION,
SPECIFIC_TYPE_NOTIFICATION_SENSOR
Values (size is 1 byte dec):
•
default value 0
•
1 - Home Security; Motion Detection, unknown location
•
2 - CO; Carbon Monoxide detected, unknown location
•
3 - CO2; Carbon Dioxide detected, unknown location
•
4 - Water Alarm; Water Leak detected, unknown location
•
5 - Heat Alarm; Overheat detected, unknown location
•
6 - Smoke Alarm; Smoke detected, unknown location
•
0 - Endpoint, I2 disabled
-sensor binary (9):
GENERIC_TYPE_SENSOR_BINARY, SPECIFIC_TYPE_NOT_USED
Values (size is 1 byte dec):
•
9 - Sensor binary
NOTE 1: After changing the values of the parameter, first exclude the device (without setting
the parameters to their default values), wait at least 30 seconds and then re-include the device!
NOTE 2: When the parameter is set to the value 9 the notifications are sent for the Home
Security notification type.
Image 1: Only input l3 is enabled (without input l2)
Содержание ZMNHDD2
Страница 18: ...EN 18 4 Package Contents Flush Dimmer Device Installation Manual...
Страница 25: ...EN 25 After Qubino installation Wiring with one switch...
Страница 26: ...EN 26 INSTALLATION WITH ON OFF SWITCH AND SCENE SWITCHES...
Страница 27: ...EN 27 INSTALLATION WITH 3 WAY SWITCH...
Страница 28: ...EN 28 INSTALLATION WITH 2 OR MORE SWITCHES CONTROLLING THE SAME LIGHT Before Qubino installation...
Страница 29: ...EN 29 2 WAY SWITCH...
Страница 30: ...EN 30 MULTI WAY SWITCHES...
Страница 31: ...EN 31 INSTALLATION WHERE THERE IS NO NEUTRAL LINE N IN SWITCH BOX Before Qubino installation...
Страница 32: ...EN 32 After Qubino installation...
Страница 38: ...EN 38 Step 2 Switch of the power supply Step 3 Connect the temperature sensor as shown below...
Страница 39: ...EN 39 Step 4 Place the temperature sensor in the switch box Step 5 Turn the fuse on...
Страница 40: ...EN 40 Step 6 Re include the device to your network...
Страница 41: ...EN 41 Step 7 Start using the temperature sensor in connection with your device...