TIMTER™ Multi
-mode Dual
Telemetry Transmitter
45
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
ENC
Machine
Encoder
Registers
This is a read only command
;
Displays machine encoder
registers in the format
ENC blk R value
Blk is one or more of four (4)
blocks specified by one hex
character; each bit is one of the
blocks
ENC 0 = 1
ENC 1 = 2
ENC 2 = 4
ENC 3 = 8
R = Register
C - Control
H - Header Words
L - Lookup Table
Value = 32 bit register value
Examples:
ENC ? ENC command Help
FO
Frequency
Offset
Offsets the synthX MHz
and the FPGA -X MHz
Example:
FO 0.0055 offsets 5.5 kHz
FO
Y
FO 0
FP
Frequency Plug
Read
Returns current value of mode
and frequency from a switch box
PF or PM
Y
FP 0