TIMTER™ Multi
-mode Dual
Telemetry Transmitter
75
Quasonix, Inc.
4.2.3.1.6 Mode
–
MO
When the mode is changed to 13 (STC) on a Dual Transmitter, channel 1 settings are automatically copied to
channel 2 so they match.
4.2.3.1.7 System Status Command
–
SY
The SY command is defined as follows.
Mode
CF Rate
Freq
Tmp
CRate
(b/s)
(Hz)
(C)
(b/s)
0
10001252
2255000000
27.0
19999948
Mode -
Current mode number (such as 0 = PCM/FM)
CF Rate -
Clock free estimated data rate. This rate is based on the external data input (TTL or RS-422) even if
internal data is presently in use (CS = 1).
Freq -
Tuned frequency
Tmp -
Current temperature
CRate -
Clock filter clock rate. This is the actual over the air bit rate, regardless of the selected data source, and
including any increases due to encoding (LDPC or convolutional). IN clock free automatic mode, it may differ from
CF Rate because it will track the bit sync rate (exact, if locked) rather than the clock free estimated rate
(approximate).