TIMTER™ Multi
-mode Dual
Telemetry Transmitter
67
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
SZ
Set Up System
Status Reporting
Selects values to be reported by
the SY command; the argument is
a string of characters that
specifies, in order, the values
included in the status report
output
Values may include:
A
–
Clock rate 0
B
–
Clock rate 1
C
–
Clock rate 2
D
–
Clock rate 3
M
–
Mode 1
N
–
Mode 2
F
–
Frequency 1
G
–
Frequency 2
T
–
Temperature 1
U
–
Temperature 2
Examples:
SZ ?
SZ command Help with
up to date list of status values
SZ
Show current values to
be included in status report
SZ MFGT Set status to show
Mode 1, Frequency 1, Frequency
2, and Temperature 1
TTS
Temperature
Table State
Displays the current state of the
temperature tables and bands
Example:
TTS
Show current band and
temperature table states
Standard
N/A
N/A