TIMTER™ Multi
-mode Dual
Telemetry Transmitter
54
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
MO
Modulation
Report or set modulation setting
Mode 6, Carrier only, is present
on every transmitter
Examples: (depending on modes
ordered)
MO
Report the modulation
setting
MO 0 Set modulation to
PCM/FM
MO 1 Set modulation to
SOQPSK-TG
MO 2 Set modulation to MULTI-
h CPM
MO 3 Set modulation to BPSK
MO 4 Set modulation to QPSK
MO 6 Carrier only, no
modulation
MO 7 Set modulation to
OQPSK
MO 8 Set modulation to
UQPSK
MO 9 Set modulation to
AUQPSK
MO 13 Set modulation to STC
Refer to section 4.2.3.1.6 for
additional MO command detail
MO 13
requires
STC
option
All other
mode
availability
dependent
on modes
ordered
Y
MO 0 or
the first
one the
customer
has
installed
on the
unit
Example:
MO 1 if
no
PCM/FM
installed;
MO 2 if
only
CPM
installed