Rack-Mount RDMS
TM
Telemetry Receiver
49
Quasonix, Inc.
Figure 86: Status Menu, Save Events
– Mem Stick
The Save Events ‘Mem Stick’ parameter message changes to Save Events ‘Ready’ a few seconds after a
valid USB flash drive is inserted.
2.
When ‘Ready’ is displayed, select the parameter and press the Enter key on the front panel keypad.
The parameter displays Save Events ‘Finished’ after the error information has successfully been saved.
3.
Remove the USB flash drive.
4.1.5.7.2 Application Update
This option allows application software updates to the RDMS™ unit without shutting down, etc.
To update application software externally:
1.
Insert the USB flash drive containing the software update into the USB port on the front panel.
Figure 87: Status Menu, App Update
– Mem Stick
If a new application is found on the USB flash drive, installation begins immediately. If no update software
is found on the USB flash drive, a Not Found message displays, as shown in Figure 88. Replace the USB
flash drive with one containing the correct application file.
2.
Remove the USB flash drive when the installation is complete.